Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

A bus coupler circuit breaker is utilized in a substation for

A

Joining the transmission line with station busbar

B

Joining main and transfer bus in a substation

C

Joining the generator with transfer

D

Joining the neutral of the generator with earth

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option B

Joining main and transfer bus in a substation

Quick Summary:

A bus coupler circuit breaker is a vital switching device used to connect two separate busbar sections in a substation. Its primary purpose is to allow for the transfer of load between the main bus and the transfer bus or to provide flexibility during maintenance without interrupting power supply.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

A bus coupler circuit breaker is a vital switching device used to connect two separate busbar sections in a substation. Its primary purpose is to allow for the transfer of load between the main bus and the transfer bus or to provide flexibility during maintenance without interrupting power supply.

ЁЯФв Key Formulas

Ibus=I1+I2I_{bus} = I_1 + I_2IbusтАЛ=I1тАЛ+I2тАЛ тАФ Summation of load currents during bus coupling

тЪЩя╕П Working Principle

During normal operation, the bus coupler breaker is typically kept open if the buses are to be isolated. When a specific bus section requires maintenance, the bus coupler is closed to parallel the two bus systems, allowing the load to be shifted from the bus under maintenance to the healthy bus, after which the sectionalizing disconnectors are opened.

ЁЯУМ Key Points
  • тЦ╕

    Used for load transfer between busbars

  • тЦ╕

    Essential for substation maintenance flexibility

  • тЦ╕

    Reduces downtime during routine maintenance of circuit breakers or isolators

  • тЦ╕

    Allows bus sectionalizing to limit short-circuit current

тЬЕ Advantages
  • тЦ╕

    Improved power system reliability

  • тЦ╕

    Operational flexibility during maintenance

  • тЦ╕

    Provision for sectioning the bus system

тЭМ Disadvantages / Limitations
  • тЦ╕

    Increased initial substation cost

  • тЦ╕

    Requirement for additional control and relaying protection

  • тЦ╕

    Increased complexity in switching operations

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Double busbar systems

  • тЦ╕

    Main and transfer busbar schemes

  • тЦ╕

    Substations where high reliability is mandated

ЁЯУД Additional Information
  • тЦ╕

    A bus coupler is also known as a bus tie breaker.

  • тЦ╕

    Option A is incorrect as a feeder circuit breaker performs this task.

  • тЦ╕

    Option D is incorrect as neutral earthing is performed via Grounding Transformers or NGRs.

ЁЯУК Diagram / Illustration
Main BusbarTransfer BusbarCBBus Coupler Circuit Breaker
тЬЕ

B is correct тАФ The bus coupler circuit breaker specifically acts as the bridge to connect the main busbar to the transfer busbar in a substation arrangement.

Core Concepts Used
Click any tag to open in AI Tutor
Substation Configuration Busbar Schemes Switchgear Protection
ЁЯТб EXAM TIP

Remember that 'Bus Coupler' is for bus-to-bus switching, while 'Feeder' breakers are for line-to-bus connections; always distinguish between the two for substation layout questions.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______