Join 60,000+ competitive exam aspirants
A large diversity factor of the load in a power system
Reduces the installation cost
Increases the installation cost
Does not affect the installation cost
Insufficient data
Reduces the installation cost
A high diversity factor indicates that individual peak loads of different consumers do not occur simultaneously. Consequently, the actual maximum demand on the power station is significantly lower than the sum of individual maximum demands, leading to a smaller required capacity for generation and transmission equipment.
A high diversity factor indicates that individual peak loads of different consumers do not occur simultaneously. Consequently, the actual maximum demand on the power station is significantly lower than the sum of individual maximum demands, leading to a smaller required capacity for generation and transmission equipment.
Diversity┬аFactor=SimultaneousMaximumDemandonSystemтИСi=1nтАЛMaximumDemandiтАЛтАЛ тАФ The ratio expressing the temporal dispersion of peak loads.
The diversity factor is defined as the ratio of the sum of individual maximum demands to the simultaneous maximum demand on the system. When this factor is high, it implies that the aggregate peak load on the distribution system is lower. Since system components like transformers, feeders, and generators must be sized based on the maximum load, a higher diversity factor allows for smaller, less expensive electrical infrastructure.
Diversity factor is always greater than 1.
A higher diversity factor means a flatter aggregate load curve.
Lower aggregate peak demand reduces the rating and thermal stress on power equipment.
Capital expenditure is inversely proportional to the diversity factor.
Reduces the cost of generation equipment
Increases system utilization efficiency
Lowers the cost of transmission and distribution networks
Load forecasting in distribution network design
Power system planning and infrastructure sizing
Tariff structure development for utility consumers
Higher diversity factor results in a more stable base load and reduces the necessity for expensive peak-load power plants.
Option B is incorrect because high diversity leads to better utilization of equipment, not higher costs. Option C is wrong because installation cost is directly tied to the maximum peak rating, which is determined by the diversity factor.
A is correct тАФ A high diversity factor indicates that individual peak loads do not coincide, which reduces the peak load seen by the system and therefore reduces the required size and cost of the infrastructure.
Always remember: Diversity Factor > 1 (benefits the utility by reducing equipment rating), whereas Load Factor < 1 (indicates the variability of the load over time).