As per IS 456:2000, the maximum compressive strain at highly compressed fiber in RCC column subjected to bending and axial compression is given by: (Consider no tension in the section).
0.0035 + 0.75 ├Ч(strain┬аat┬аthe┬аleast┬аcompressed┬аextreme┬аfiber)
0.0035 - 0.75 ├Ч(strain┬аat┬аthe┬аleast┬аcompressed┬аextreme┬аfiber)
0.002 + 0.75 ├Ч(strain┬аat┬аthe┬аleast┬аcompressed┬аextreme┬аfiber)
0.002 - 0.75 ├Ч(strain┬аat┬аthe┬аleast┬аcompressed┬аextreme┬аfiber)
0.0035 - 0.75 ├Ч(strain┬аat┬аthe┬аleast┬аcompressed┬аextreme┬аfiber)
According to IS 456:2000, for columns subjected to axial load and bending, the strain distribution across the section is assumed to be linear. When the entire section is under compression, the maximum compressive strain at the highly compressed fiber is constrained by the strain gradient, ensuring that the strain does not exceed the limit of 0.0035 at the extreme fiber, reduced by the gradient effect.
IS 456:2000, Cl. 39.1, Note
According to IS 456:2000, for columns subjected to axial load and bending, the strain distribution across the section is assumed to be linear. When the entire section is under compression, the maximum compressive strain at the highly compressed fiber is constrained by the strain gradient, ensuring that the strain does not exceed the limit of 0.0035 at the extreme fiber, reduced by the gradient effect.
╧╡maxтАЛ=0.0035тИТ0.75├Ч╧╡minтАЛ тАФ where ╧╡maxтАЛ is the maximum strain and ╧╡minтАЛ is the strain at the least compressed fiber
The design of columns under combined axial compression and uniaxial or biaxial bending is based on the strain compatibility approach. The maximum compressive strain at the highly compressed edge is limited to 0.0035. When the neutral axis lies outside the section, the strain at the least compressed fiber is positive (compressive). The formula 0.0035тИТ0.75├Ч(strain┬аat┬аthe┬аleast┬аcompressed┬аfiber) accounts for the linear strain profile ensuring structural safety under high axial loads.
The strain distribution across the depth of the column section is assumed to be linear.
The maximum compressive strain in concrete at failure is taken as 0.0035.
This specific reduction formula applies when the neutral axis lies outside the cross-section (i.e., the entire section is in compression).
The factor 0.75 is empirical and used to account for the strain gradient in highly compressed members.
Ensures safety against crushing of concrete in eccentric loading scenarios.
Provides a consistent basis for developing interaction diagrams (P-M curves).
Complexity in manual calculation for biaxial bending.
Requires iterative methods for accurate strain determination.
Design of reinforced concrete columns.
Analysis of short and slender columns under combined load.
When the entire section is in compression, the neutral axis is situated outside the section, resulting in compressive strains throughout the column depth.
Option A and C are incorrect because they imply strain greater than 0.0035, which exceeds the ultimate compressive strain limit of concrete.
Option D is incorrect as it does not follow the code-mandated reduction coefficient.
B is correct тАФ As per IS 456:2000, for a section subjected to axial compression and bending where the entire section is in compression, the maximum compressive strain is 0.0035тИТ0.75├Ч(strain┬аat┬аthe┬аleast┬аcompressed┬аextreme┬аfiber).
Always remember that in RCC design, the ultimate compressive strain in concrete at the extreme fiber is 0.0035 for bending, but it is adjusted based on the axial load contribution.