Buchholz relay is provided on the transformer to
indicate minor faults inside the transformers.
indicate minor & major faults and isolate the transformer during a major fault.
isolate the transformer during a major fault.
indicate major fault inside the transformers.
indicate minor & major faults and isolate the transformer during a major fault.
The Buchholz relay is a gas-actuated protective device installed in oil-immersed transformers between the main tank and the conservator. It serves as a dual-stage protection system, capable of detecting both minor incipient faults (by accumulation of gas) and severe internal faults (by detecting oil surge) to disconnect the transformer from the supply.
The Buchholz relay is a gas-actuated protective device installed in oil-immersed transformers between the main tank and the conservator. It serves as a dual-stage protection system, capable of detecting both minor incipient faults (by accumulation of gas) and severe internal faults (by detecting oil surge) to disconnect the transformer from the supply.
PтИЭdtd╬жтАЛ тАФ relating pressure surge to sudden flux/insulation breakdown
VgasтАЛтИЭтИлI2Rdt тАФ gas generation proportional to heat dissipation
The relay contains two floats: the upper float is sensitive to slow gas accumulation caused by minor faults (like local heating or partial discharge), which triggers an alarm. The lower float is sensitive to sudden, high-velocity oil flow (pressure surges) resulting from major winding or insulation failures, which trips the circuit breaker to isolate the transformer.
Buchholz relay is specifically designed for oil-immersed transformers.
It is a gas-operated relay installed in the pipe connecting the conservator to the transformer tank.
The alarm contact is connected to the upper float, while the trip contact is connected to the lower float.
It cannot be used for dry-type or air-cooled transformers.
Capable of detecting incipient internal faults before they become catastrophic.
Provides both alarm and trip functionality.
Only applicable to oil-immersed transformers equipped with a conservator.
False alarms can occur due to vibration or air bubbles in the oil.
Large oil-immersed power transformers.
Distribution transformers exceeding 500 kVA rating.
Standard operation requires the oil level to be maintained correctly; otherwise, the Buchholz relay may give false indications.
Option A is incomplete as it ignores the trip function; Option C is incomplete as it ignores minor fault sensing.
B is correct тАФ the Buchholz relay functions as a dual-protection device that signals minor faults via an alarm and isolates the transformer during major faults via a trip contact.
Always remember that Buchholz relays are 'gas-actuated'; they detect the physical manifestation of a fault (gas bubbles or oil displacement) rather than electrical parameters like current or voltage.