Join 60,000+ competitive exam aspirants
Capacitance of a transmission line
Increases with increase in its length
Decrease decreases with increase in its length
Remains same with increase in its length
None of above
Increases with increase in its length
The capacitance of a transmission line is directly proportional to its length. As the length of the line increases, the physical surface area available for charge accumulation increases, thereby increasing the total capacitance of the line.
The capacitance of a transmission line is directly proportional to its length. As the length of the line increases, the physical surface area available for charge accumulation increases, thereby increasing the total capacitance of the line.
C=C0тАЛ├Чl тАФ where C0тАЛ is the capacitance per unit length and l is the total length
C=ln(D/r)2╧А╧╡0тАЛтАЛ тАФ capacitance per unit length for a single phase line
A transmission line acts like a two-conductor capacitor where the conductors serve as plates separated by a dielectric medium (air). The capacitance per unit length C0тАЛ is constant for a given geometry. Therefore, the total capacitance C for a line of length l is calculated as C=C0тАЛ├Чl. Thus, increasing the length l linearly increases the total capacitance C.
Capacitance is a shunt parameter in transmission line modeling.
The effect of capacitance is significant in long transmission lines (>250 km).
It contributes to the Ferranti effect, where receiving end voltage exceeds sending end voltage under light load conditions.
Capacitance is independent of the operating voltage but depends on conductor geometry and spacing.
Useful for reactive power compensation studies
Essential for calculating charging current in long lines
Causes Ferranti effect
Increases charging current, impacting the rating of line equipment
Power system steady-state analysis
Load flow studies
Surge impedance loading calculations
Option B is incorrect because capacitance does not decrease with length; it is a physical property defined by geometry.
Option C is incorrect because the total capacitance is an extensive property, meaning it scales with the physical extent of the conductor.
Capacitance per unit length is typically measured in F/m (Farads per meter).
A is correct тАФ The total capacitance of a transmission line is directly proportional to its length because it acts as an extensive physical property of the conductor arrangement.
Always remember: Series parameters (Resistance and Inductance) are also proportional to length, whereas Shunt Conductance (G) and Shunt Capacitance (C) are also proportional to length.