Join 60,000+ competitive exam aspirants
Field diverter method of speed control of a DC series motor gives speed above rated one due to reduction of
Line current
Field current
Armature current
None of the above
Field current
Remember the fundamental formula: Speed is inversely proportional to Flux (N proportional to 1/phi). Diverting field current reduces flux, which directly increases speed above the rated value.
Remember the fundamental formula: Speed is inversely proportional to Flux (N proportional to 1/phi). Diverting field current reduces flux, which directly increases speed above the rated value.
Recall the Speed Formula
The speed of a DC motor is governed by N = k(V - IaRa)/phi. For a series motor, N is inversely proportional to the magnetic flux (phi).
Analyze Field Diverter Function
A field diverter is a variable resistor connected in parallel with the series field winding. By adjusting this resistor, we divert some portion of the total line current away from the series field winding.
Determine Speed Change
Lowering the current through the field winding decreases the magnetic flux (phi). Since flux is in the denominator of the speed equation, reducing flux causes the speed (N) to rise above the rated value.
A: The line current remains largely unchanged; the diverter only redistributes it. C: Armature current does not decrease; in fact, the motor draws more current to maintain torque. D: The speed increase is directly tied to the field flux reduction.
B is correct because the field diverter reduces the current flowing through the field coils, which decreases the magnetic flux, thereby increasing the rotational speed of the motor.
Whenever you see 'diverter' in DC machines, think 'bypass' and 'weakening the field' which always results in speed increase above base speed.