Join 60,000+ competitive exam aspirants
For 250 volt DC Shunt Motor the armature and field resistance are 0.5 ohms and 250 ohms respectively. What will be the back e.m.f. produced when it takes a load current of 21A.
220 V
150 V
240 V
280 V
240 V
The back EMF (EbтАЛ) of a DC shunt motor is calculated using the Kirchhoff's Voltage Law applied to the armature circuit, defined as EbтАЛ=VтИТIaтАЛRaтАЛ. For a shunt motor, the load current (ILтАЛ) is the sum of armature current (IaтАЛ) and field current (IshтАЛ), where IshтАЛ=RshтАЛVтАЛ.
The back EMF (EbтАЛ) of a DC shunt motor is calculated using the Kirchhoff's Voltage Law applied to the armature circuit, defined as EbтАЛ=VтИТIaтАЛRaтАЛ. For a shunt motor, the load current (ILтАЛ) is the sum of armature current (IaтАЛ) and field current (IshтАЛ), where IshтАЛ=RshтАЛVтАЛ.
EbтАЛ=VтИТIaтАЛRaтАЛ тАФ Back EMF equation
IaтАЛ=ILтАЛтИТRshтАЛVтАЛ тАФ Armature current for shunt motor
As the motor rotates, the armature conductors cut the magnetic flux, inducing a back EMF that opposes the supply voltage. The actual armature current is the difference between the supply current and the field current. By subtracting the voltage drop across the armature resistance (IaтАЛRaтАЛ) from the supply voltage (V), we find the internal back EMF.
In a DC shunt motor, the field winding is connected in parallel with the armature.
The back EMF is always less than the applied terminal voltage when the motor is running under load.
The armature current IaтАЛ is strictly the line current minus the shunt field current.
Maintains constant speed characteristics.
Adjustable speed control via field flux variation.
Starting torque is limited compared to series motors.
Efficiency drops if shunt field current is high.
Lathe machines
Centrifugal pumps and blowers
Given: V=250V, RaтАЛ=0.5╬й, RshтАЛ=250╬й, ILтАЛ=21A.
First, calculate field current: IshтАЛ=250250тАЛ=1A.
Then, find armature current: IaтАЛ=ILтАЛтИТIshтАЛ=21тИТ1=20A.
Finally, back EMF: EbтАЛ=250тИТ(20├Ч0.5)=250тИТ10=240V.
Option B (150V) is a common error if one neglects to subtract the field current from the total line current.
C is correct тАФ The back EMF is calculated as 240V after subtracting the armature voltage drop (10V) from the supply voltage (250V).
Always verify if the given current is the line current or armature current; in shunt motors, they are rarely identical due to the parallel field branch.