Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

For limiting the short circuit┬а current

A

Reactors are used

B

Resistors are used

C

Capacitors are used

D

Any of above

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option A

Reactors are used

Quick Summary:

Current limiting reactors are inductive coils connected in series with the power system to increase the total series reactance. By increasing the reactance, they reduce the magnitude of fault current during a short-circuit condition, thereby protecting circuit breakers and other equipment.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

Current limiting reactors are inductive coils connected in series with the power system to increase the total series reactance. By increasing the reactance, they reduce the magnitude of fault current during a short-circuit condition, thereby protecting circuit breakers and other equipment.

ЁЯФв Key Formulas

Isc=VjXtotalI_{sc} = \frac{V}{jX_{total}}IscтАЛ=jXtotalтАЛVтАЛ тАФ The fault current is inversely proportional to the total reactance in the circuit.

XL=2╧АfLX_L = 2\pi f LXLтАЛ=2╧АfL тАФ The reactance provided by the inductor, which is directly proportional to frequency and inductance.

тЪЩя╕П Working Principle

During a short-circuit, the system impedance drops significantly, leading to an extremely high fault current. According to Ohm's law, If=VZeqI_f = \frac{V}{Z_{eq}}IfтАЛ=ZeqтАЛVтАЛ. By adding a reactor (XLX_LXLтАЛ) in series, the equivalent impedance ZeqZ_{eq}ZeqтАЛ increases to R2+(Xsystem+XL)2\sqrt{R┬▓ + (X_{system} + X_L)^2}R2+(XsystemтАЛ+XLтАЛ)2тАЛ, which effectively limits the short-circuit current to a safe value for the protective switchgear.

ЁЯУМ Key Points
  • тЦ╕

    Reactors provide high impedance under fault conditions to limit current.

  • тЦ╕

    They are typically air-cored to avoid saturation during heavy fault currents.

  • тЦ╕

    They are categorized as generator reactors, feeder reactors, or bus-bar reactors based on placement.

тЬЕ Advantages
  • тЦ╕

    Reduces mechanical and thermal stress on equipment during faults.

  • тЦ╕

    Allows the use of lower-rated (cheaper) circuit breakers.

  • тЦ╕

    Minimizes the spread of disturbances to healthy parts of the system.

тЭМ Disadvantages / Limitations
  • тЦ╕

    Introduces continuous voltage drop under normal operating conditions.

  • тЦ╕

    Increases the total reactive power consumption of the system.

  • тЦ╕

    Can negatively affect steady-state voltage stability.

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Power generating stations

  • тЦ╕

    Transmission and distribution substations

ЁЯУД Additional Information
  • тЦ╕

    Reactors are preferred over resistors because resistors would cause significant real power (I2R)I^2R)I2R) losses during normal operation, whereas reactors cause negligible power dissipation.

  • тЦ╕

    Capacitors are generally used for power factor improvement, not for current limiting.

ЁЯУК Diagram / Illustration
Short Circuit Current LimitationSourceReactor (XL)Fault Point
тЬЕ

A is correct тАФ Reactors are used to provide the necessary series inductive reactance to limit the magnitude of fault current.

Core Concepts Used
Click any tag to open in AI Tutor
Short circuit fault analysis Power system protection Inductive reactance
ЁЯТб EXAM TIP

Always remember that series reactors reduce fault current, while shunt reactors are used for capacitive compensation in long EHV lines.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext