Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

How many pilot wires used in translay relay scheme?

A

2

B

3

C

4

D

5

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option A

2

Quick Summary:

The Translay relay scheme, commonly used for the protection of feeders and short transmission lines, utilizes two pilot wires to provide a balanced circulating current protection system. This scheme is a form of unit protection that compares the currents at the two ends of the protected zone.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

The Translay relay scheme, commonly used for the protection of feeders and short transmission lines, utilizes two pilot wires to provide a balanced circulating current protection system. This scheme is a form of unit protection that compares the currents at the two ends of the protected zone.

ЁЯФв Key Formulas

IR=I1тИТI2I_{R} = I_{1} - I_{2}IRтАЛ=I1тАЛтИТI2тАЛ тАФ Net relay operating current in the pilot circuit

Vp=Is├ЧZpilotV_{p} = I_{s} \times Z_{pilot}VpтАЛ=IsтАЛ├ЧZpilotтАЛ тАФ Voltage drop across pilot wire impedance

тЪЩя╕П Working Principle

The relay works on the principle of current balance. Under normal conditions or external faults, the secondary currents produced by the current transformers (CTs) at both ends circulate through the pilot wires such that no current flows through the relay coils. During an internal fault, the balance is disturbed, causing current to flow through the relay coils, which then trips the circuit breaker.

ЁЯУМ Key Points
  • тЦ╕

    Translay system is a differential protection scheme.

  • тЦ╕

    It is highly sensitive to internal faults.

  • тЦ╕

    The pilot wires carry circulating currents proportional to the line currents.

  • тЦ╕

    The scheme is generally limited to short distances due to pilot wire resistance and capacitance.

тЬЕ Advantages
  • тЦ╕

    Simple construction and installation.

  • тЦ╕

    High sensitivity for internal faults.

  • тЦ╕

    Does not require a pilot wire monitoring system for all applications.

тЭМ Disadvantages / Limitations
  • тЦ╕

    Distance limitation due to pilot wire length.

  • тЦ╕

    Susceptible to induced voltages if pilot wires are not shielded correctly.

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Protection of distribution feeders.

  • тЦ╕

    Short transmission lines in urban areas.

ЁЯУД Additional Information
  • тЦ╕

    The use of two pilot wires is sufficient because the relay operates on the difference between the rectified or phase-shifted currents derived from the primary line currents.

  • тЦ╕

    Option B, C, and D are incorrect as the standard Translay configuration specifically requires only two conductors for the pilot circuit.

ЁЯУК Diagram / Illustration
Translay Relay Pilot CircuitCT End 1CT End 22 Pilot WiresRelay Coil
тЬЕ

A is correct тАФ The Translay relay scheme requires only 2 pilot wires to establish the differential protection circuit.

Core Concepts Used
Click any tag to open in AI Tutor
Differential Protection Pilot Wire Communication Current Balance Relay
ЁЯТб EXAM TIP

Always remember that in unit protection schemes like Translay or Biased Differential, the number of pilot wires is minimized to reduce installation costs and complexity.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext