Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalEconomics for Engineers
PrevNext

HV test should be conducted if the insulation resistance is ____________ the value defined in IS 4722.

A

greater than

B

less than

C

for any value

D

not depend on IR value

Correct Answer

Concept & PrincipleElectricalEconomics for Engineers
Option A

greater than

Quick Summary: According to IS 4722, a High Voltage (HV) test is a dielectric withstand test used to verify the integrity of the insulation system of rotating electrical machines. This test should only be performed after the insulation resistance (IR) has been measured and confirmed to be above the minimum permissible value defined by the standard to prevent damage to faulty or moisture-laden insulation during the high-voltage stress.

💡 Explanation

According to IS 4722, a High Voltage (HV) test is a dielectric withstand test used to verify the integrity of the insulation system of rotating electrical machines. This test should only be performed after the insulation resistance (IR) has been measured and confirmed to be above the minimum permissible value defined by the standard to prevent damage to faulty or moisture-laden insulation during the high-voltage stress.

🔢 Key Formulas

RIR≥Vrated(kV)+11MΩR_{IR} \ge \frac{V_{rated(kV)} + 1}{1} M\OmegaRIR​≥1Vrated(kV)​+1​MΩ — Minimum IR value requirement (Approximate for many machines as per IS standards)

⚙️ Working Principle

The insulation resistance test (Megger test) is a non-destructive check that ensures the insulation is dry and free from surface contamination. Applying high voltage to insulation with low resistance (e.g., due to moisture or physical breakdown) can cause destructive arcing or puncture. Therefore, the IR measurement serves as a prerequisite safety gate before subjecting the machine windings to the stress of the HV proof test.

📌 Key Points
  • ▸

    IS 4722 regulates the specifications for rotating electrical machines.

  • ▸

    IR test is mandatory to prevent breakdown during high-potential testing.

  • ▸

    HV test validates the machine's ability to withstand transient overvoltages.

  • ▸

    The HV test voltage is generally defined as (2×Vrated+1000)V(2 \times V_{rated} + 1000)V(2×Vrated​+1000)V for a duration of one minute.

✅ Advantages
  • ▸

    Ensures machine safety before applying high voltage stress.

  • ▸

    Identifies insulation degradation early.

  • ▸

    Prevents catastrophic failure during commissioning.

❌ Disadvantages / Limitations
  • ▸

    HV test can potentially weaken 'borderline' insulation if repeated excessively.

  • ▸

    Requires specialized high-voltage test equipment.

🛠️ Applications / Uses
  • ▸

    Routine testing of AC and DC motors.

  • ▸

    Commissioning of generators and large industrial alternators.

  • ▸

    Post-repair quality assurance of electrical windings.

📄 Additional Information
  • ▸

    If the IR value is found to be below the limit, the machine must be dried out or cleaned before performing the HV test to avoid winding puncture.

  • ▸

    Option B (less than) is incorrect because performing an HV test on low-resistance insulation usually results in a permanent short-circuit or insulation failure.

📊 Diagram / Illustration
Insulation Testing SequenceIR MeasurementHV TestRequires IR > Minimum Specified Value
✅

A is correct — HV testing is a proof test that should only be performed after verifying that the insulation is dry and has sufficient resistance (exceeding the IS 4722 limit).

Core Concepts Used
Click any tag to open in AI Tutor
Dielectric Withstand Test Insulation Resistance (IR) IS 4722 Standard Electrical Safety
💡 EXAM TIP

Always remember that in electrical testing, non-destructive tests (IR, Polarization Index) must precede destructive or high-stress tests (HV, Surge comparison) to safeguard the equipment.

Related Questions

ElectricalEconomics for Engineers
Wha is the indication of the second digit in IP code?
ElectricalEconomics for Engineers
Wha is the indication of the first digit in IP code?
ElectricalEconomics for Engineers
The designation used for the _____________ consists of the letters IP followed by two characteristic numerals si
ElectricalEconomics for Engineers
What is IP code in rotating machine?
ElectricalEconomics for Engineers
In which of the following enclosure, we can not stop water from entering into the machine?