Join 60,000+ competitive exam aspirants
In a DC shunt generator working on load, the brushes are moved forward in the direction of rotation, as a result of this, the commutation will
improve and terminal voltage will rise
improve but the terminal voltage will fall
worsen and terminal voltage will rise
worsen and terminal voltage will fall
improve and terminal voltage will rise
Remember the mnemonic 'Forward Shift = Flux Support': moving brushes forward in a generator creates a demagnetizing effect but also induces a boosting flux component, improving sparkless commutation and increasing voltage.
Remember the mnemonic 'Forward Shift = Flux Support': moving brushes forward in a generator creates a demagnetizing effect but also induces a boosting flux component, improving sparkless commutation and increasing voltage.
Analyze Armature Reaction
In a DC generator, shifting brushes forward (in the direction of rotation) helps in moving the brushes towards the new Magnetic Neutral Axis (MNA) shifted by armature reaction, which reduces sparking (improves commutation).
Evaluate Terminal Voltage
Shifting brushes forward in a generator acts in a way that counteracts the demagnetizing effect of the armature reaction, thereby increasing the net flux per pole and raising the terminal voltage.
B: Commutation improves, but the voltage rise is a direct result of brush position in generators. C: Commutation does not worsen; it improves due to alignment with MNA. D: Commutation does not worsen, and voltage rises, not falls.
A is correct because shifting brushes forward in a DC generator aligns them with the shifted magnetic neutral axis to improve commutation and provides a boosting effect that increases the terminal voltage.
Always distinguish between motors and generators: in motors, brush shift is opposite to rotation to improve commutation; in generators, it is in the direction of rotation.