Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

In overhead line which type of faults occurs nearly 85%?

A

LLL

B

LG

C

LLG

D

LL

Correct Answer

Concept & PrincipleElectricalPower System
Option B

LG

Quick Summary: In overhead transmission and distribution systems, Line-to-Ground (LG) faults are the most common, accounting for approximately 85% of all system faults. This high frequency is primarily due to the exposure of lines to external environmental factors like lightning, falling trees, and birds.

💡 Explanation

In overhead transmission and distribution systems, Line-to-Ground (LG) faults are the most common, accounting for approximately 85% of all system faults. This high frequency is primarily due to the exposure of lines to external environmental factors like lightning, falling trees, and birds.

🔢 Key Formulas

If(LG)=3EZ1+Z2+Z0I_{f(LG)} = \frac{3E}{Z_1 + Z_2 + Z_0}If(LG)​=Z1​+Z2​+Z0​3E​ — where If(LG)I_{f(LG)}If(LG)​ is the LG fault current, EEE is phase voltage, and Z1,Z2,Z0Z_1, Z_2, Z_0Z1​,Z2​,Z0​ are positive, negative, and zero sequence impedances.

⚙️ Working Principle

An LG fault occurs when a single phase conductor makes physical contact with the ground or a grounded object (such as a steel tower or cross-arm). This creates a low-impedance return path for the fault current, resulting in a sudden surge in current and potential system unbalance, which the protective relaying system must isolate.

📌 Key Points
  • ▸

    LG faults are the most frequent type of unsymmetrical fault.

  • ▸

    Most faults are transient in nature, often caused by lightning or flashovers.

  • ▸

    Symmetrical faults (LLL) are the least frequent but most severe in magnitude.

  • ▸

    Zero sequence impedance plays a crucial role in calculating LG fault current magnitudes.

✅ Advantages
  • ▸

    Most protective relaying schemes are optimized to detect LG faults quickly.

  • ▸

    Easier to clear compared to three-phase faults due to lower magnitude.

❌ Disadvantages / Limitations
  • ▸

    Frequent interruptions impact power quality.

  • ▸

    May cause significant transient overvoltages on healthy phases.

🛠️ Applications / Uses
  • ▸

    Transmission line protection design.

  • ▸

    Switchgear sizing and insulation coordination.

📄 Additional Information
  • ▸

    Symmetrical faults (LLL) account for only about 5% of total faults.

  • ▸

    LL and LLG faults account for the remaining 10% of faults.

  • ▸

    The high incidence of LG faults justifies the widespread use of auto-reclosing circuit breakers in distribution networks.

📊 Diagram / Illustration
Fault Distribution OverviewLG (85%)Others (15%)Line-GndPhase-Phase
✅

B is correct — Line-to-Ground (LG) faults represent the vast majority of system faults in overhead lines due to atmospheric and environmental interactions.

Core Concepts Used
Click any tag to open in AI Tutor
Unsymmetrical faults Symmetrical components Power system protection
💡 EXAM TIP

Always remember that in power systems, frequency of occurrence is inversely proportional to fault severity; LG faults occur most often but have lower magnitude than LLL faults.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext