In shaded pole single-phase induction motor. Share of Unshaded and shaded part in the pole is __________ & _________ respectively.
1/2 & 1/2
1/3 & 2/3
2/3 & 1/3
2/5 & 3/5
2/3 & 1/3
In a shaded pole induction motor, the stator pole is split into two unequal sections: a larger unshaded portion and a smaller shaded portion. The unshaded part constitutes approximately 2/3 of the pole arc, while the shaded part, which incorporates a copper shading ring, covers the remaining 1/3.
In a shaded pole induction motor, the stator pole is split into two unequal sections: a larger unshaded portion and a smaller shaded portion. The unshaded part constitutes approximately 2/3 of the pole arc, while the shaded part, which incorporates a copper shading ring, covers the remaining 1/3.
╬жsтАЛ=╬жuтАЛтИатИТ╬╕ тАФ Flux in shaded part lags the flux in unshaded part
TstartтАЛтИЭsin(╬╕) тАФ Starting torque depends on the phase displacement angle ╬╕
The copper shading ring causes a time lag in the magnetic flux passing through the shaded portion compared to the unshaded portion. This phase difference between the fluxes in the two sections creates a rotating magnetic field, which is essential to initiate starting torque in the single-phase motor.
The shading ring acts as a short-circuited secondary winding.
The induced current in the copper ring opposes the change in flux, creating the phase shift.
Shaded pole motors are generally used for low-power applications (fans, toys).
These motors have very low starting torque and low efficiency.
Extremely simple construction
Low manufacturing cost
Maintenance-free
Very low starting torque
Low efficiency
Power factor is quite low
Small table fans
Hair dryers
Record players and projectors
Relays and control circuits
The ratio of 2/3 to 1/3 is a standard design heuristic to ensure sufficient starting torque without excessive core losses.
If the shaded portion were too large, the motor would experience higher iron losses and reduced efficiency.
C is correct тАФ The unshaded pole arc occupies approximately 2/3 of the total pole area, while the shaded section occupies 1/3.
Remember that shaded pole motors are the only single-phase motors that do not use centrifugal switches or capacitors for starting; the phase split is achieved entirely through magnetic flux distortion.