Join 60,000+ competitive exam aspirants
In speed control of DC shunt motor by varying field flux, what may be the value of field regulator?
1 ohm
10 ohm
100 ohm
1000 ohm
1000 ohm
In DC shunt motor speed control by flux weakening, a variable resistor (field regulator) is connected in series with the shunt field winding. A value around 100 ╬й is typical for standard laboratory or industrial fractional to low horsepower shunt motors to achieve the desired range of flux reduction and speed increase.
In DC shunt motor speed control by flux weakening, a variable resistor (field regulator) is connected in series with the shunt field winding. A value around 100 ╬й is typical for standard laboratory or industrial fractional to low horsepower shunt motors to achieve the desired range of flux reduction and speed increase.
N=KтЛЕ╬жEbтАЛтАЛ тАФ Speed equation for DC motor
IfтАЛ=RshтАЛ+RregтАЛVтАЛ тАФ Field current dependence on regulator resistance
The speed of a DC motor is inversely proportional to the flux per pole (╧ЙтИЭ╬ж1тАЛ). By increasing the resistance in the shunt field circuit using a field regulator, the field current (IfтАЛ=RfтАЛ+RregтАЛVтАЛ) decreases, causing the flux ╬ж to reduce and the motor speed to increase above the rated speed. The regulator must be designed to handle the field current and provide sufficient resistance to weaken the flux effectively without exceeding the motor's safe operating speed limit.
Flux control method is used for speeds above the rated speed (field weakening).
Increasing field regulator resistance decreases shunt field current.
The shunt field circuit resistance is typically high, and the regulator must be capable of significant ohmic variation to influence the flux.
100 ╬й is a practical, standard value for such shunt field regulators.
Efficient method as power loss in field circuit is small.
Easy to implement with a simple series rheostat.
Allows smooth speed control above base speed.
Not suitable for speeds below rated speed.
Speed control range is limited by magnetic saturation and commutation.
High speeds may lead to instability or mechanical failure.
Machine tools
Conveyor systems
Fans and pumps where higher-than-rated speeds are required
If the field current is reduced too much, the motor speed can reach dangerous levels due to the inherent inverse relationship.
Options A, B, and C are typically too low for standard 220V/240V shunt field circuits, which usually have resistances in the hundreds of ohms.
D is correct тАФ A 100 ohm field regulator provides the necessary resistance variation to significantly weaken the flux and control the speed of a DC shunt motor.
Always remember that flux control (NтИЭ1/╬ж) is for speeds above rated, while armature voltage control (NтИЭV) is for speeds below rated.