In split-phase motor, what is the role of auxiliary winding?
It is used to create stator RMF
to provide better running power factor
to decrease harmonic
to control starting speed
It is used to create stator RMF
A single-phase induction motor produces a pulsating magnetic field rather than a rotating magnetic field (RMF), rendering it self-starting incapable. The auxiliary winding (or starting winding), along with the main winding, creates a two-phase system from a single-phase supply. This creates a rotating magnetic field in the stator to produce the necessary starting torque.
A single-phase induction motor produces a pulsating magnetic field rather than a rotating magnetic field (RMF), rendering it self-starting incapable. The auxiliary winding (or starting winding), along with the main winding, creates a two-phase system from a single-phase supply. This creates a rotating magnetic field in the stator to produce the necessary starting torque.
TsтАЛтИЭImтАЛIaтАЛsin╬▒ тАФ Starting torque proportional to main current (ImтАЛ), auxiliary current (IaтАЛ), and phase angle (╬▒)
╬▒=╬╕mтАЛтИТ╬╕aтАЛ тАФ Phase angle difference between main and auxiliary winding currents
According to the double revolving field theory, a single-phase alternating current sets up two counter-rotating magnetic fields of equal magnitude, resulting in zero net torque at standstill. When the auxiliary winding is connected in parallel with the main winding, it introduces a phase difference (ideally 90┬░) between their currents due to different resistance-to-reactance (R/X) ratios. This phase displacement creates a net rotating magnetic field, enabling the rotor to start turning.
The main winding has high inductance and low resistance, whereas the auxiliary winding has high resistance and low inductance.
The phase difference ╬▒ between main and auxiliary currents in a resistance split-phase motor is typically around 30┬░ to 40┬░.
Once the motor reaches about 75% to 80% of synchronous speed, a centrifugal switch disconnects the auxiliary winding to prevent overheating.
Simple construction and low initial cost
Reliable self-starting mechanism without needing external polyphase power
Low starting torque (typically 150% to 200% of full load torque)
Higher starting current and low starting power factor
Small fans and blowers
Centrifugal pumps
Washing machines and small machine tools
| Feature | Main Winding | Auxiliary Winding |
|---|---|---|
Resistance (R) | Low resistance | High resistance |
Inductive Reactance (XLтАЛ) | High reactance | Low reactance |
Operation | Remains connected continuously | Disconnected by centrifugal switch at ~75% speed |
Option B is incorrect because capacitors are used to significantly improve power factor, whereas the split-phase auxiliary winding is mainly resistive.
Option C is incorrect as harmonics are mitigated through coil pitch, distribution, or skewing, not the auxiliary winding.
Option D is incorrect because starting speed is determined by motor poles and supply frequency (NsтАЛ=P120fтАЛ), not by the auxiliary winding.
A is correct тАФ The auxiliary winding produces a phase-displaced current relative to the main winding, creating the necessary stator rotating magnetic field (RMF) for self-starting.
Remember that to reverse the direction of rotation of a split-phase induction motor, you must reverse the connections of EITHER the main winding OR the auxiliary winding, but NOT both.