Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalEconomics for Engineers
PrevNext

In the HV test of three-phase induction motor, The full test voltage shall then be maintained for ________ .

A

min

B

min

C

min

D

30 sec

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalEconomics for Engineers
Option A

min

Quick Summary:

According to IS 325 and IEC 60034-1 standards for rotating electrical machines, the High Voltage (HV) test (also known as the dielectric withstand test) requires applying a specified test voltage between the windings and the frame for a duration of exactly 1 minute. This ensures that the insulation system can withstand potential transient overvoltages during operation without breakdown.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

According to IS 325 and IEC 60034-1 standards for rotating electrical machines, the High Voltage (HV) test (also known as the dielectric withstand test) requires applying a specified test voltage between the windings and the frame for a duration of exactly 1 minute. This ensures that the insulation system can withstand potential transient overvoltages during operation without breakdown.

ЁЯФв Key Formulas

Vtest=2Vrated+1000V_{test} = 2V_{rated} + 1000VtestтАЛ=2VratedтАЛ+1000 тАФ The standard formula used to determine the test voltage for electrical machine windings in Volts.

тЪЩя╕П Working Principle

The HV test is a destructive or proof test that stresses the insulation dielectric. By maintaining Vtest=2Vrated+1000VV_{test} = 2V_{rated} + 1000VVtestтАЛ=2VratedтАЛ+1000V for a 60-second duration, the test checks for localized defects, moisture absorption, or mechanical damage in the insulation. If the insulation can hold the leakage current within permissible limits for this duration, it is deemed fit for industrial service.

ЁЯУМ Key Points
  • тЦ╕

    The 1-minute duration is mandatory for dielectric integrity verification.

  • тЦ╕

    The test is performed between the windings and the machine frame (earth).

  • тЦ╕

    Testing beyond 1 minute may lead to unnecessary thermal degradation of healthy insulation.

  • тЦ╕

    The leakage current must remain stable throughout the test duration.

тЬЕ Advantages
  • тЦ╕

    Detects hidden insulation defects effectively.

  • тЦ╕

    Ensures safety of personnel and equipment against ground faults.

тЭМ Disadvantages / Limitations
  • тЦ╕

    High-stress testing can occasionally accelerate aging of marginal insulation.

  • тЦ╕

    Requires high-precision equipment to monitor leakage current.

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Routine testing of three-phase induction motors.

  • тЦ╕

    Post-repair insulation verification in workshops.

ЁЯУД Additional Information
  • тЦ╕

    The 1-minute time constant is standard across most electrical manufacturing protocols including IEEE, NEMA, and IS.

  • тЦ╕

    Options B, C, and D are incorrect because they provide durations that do not comply with the standard dielectric test procedure for induction machines.

ЁЯУК Diagram / Illustration
HV Dielectric Test StandardDuration = 60 seconds
Applied Voltage: Vtest=2Urated+1000VV_{test} = 2U_{rated} + 1000\text{V}VtestтАЛ=2UratedтАЛ+1000V
Condition: Insulation must not fail/arc
тЬЕ

A is correct тАФ The standard duration for a High Voltage test on a three-phase induction motor is 1 minute to ensure dielectric stability.

Core Concepts Used
Click any tag to open in AI Tutor
Dielectric Withstand Test Insulation Resistance Rotating Machine Standards
ЁЯТб EXAM TIP

Remember that while the HV test is for 1 minute, Insulation Resistance (IR) values are typically recorded after 60 seconds of applying a DC Megger voltage to allow for capacitive charging current to stabilize.

Related Questions

ElectricalEconomics for Engineers
Wha is the indication of the second digit in IP code?
ElectricalEconomics for Engineers
Wha is the indication of the first digit in IP code?
ElectricalEconomics for Engineers
The designation used for the _____________ consists of the letters IP followed by two characteristic numerals signifying conformity with the condition
ElectricalEconomics for Engineers
What is IP code in rotating machine?
ElectricalEconomics for Engineers
In which of the following enclosure, we can not stop water from entering into the machine?

Discussion (0)

Loading discussion...
PrevNext