Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Lightening arrester should be located

A

Near the circuit breaker

B

Away from the circuit breaker

C

Near the transformer

D

Away from the transformer

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option C

Near the transformer

Quick Summary:

A lightning arrester is placed as close to the transformer as possible to minimize the length of the conductor between them. This placement ensures that surge voltages resulting from traveling waves are clamped before reaching the transformer's sensitive insulation.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

A lightning arrester is placed as close to the transformer as possible to minimize the length of the conductor between them. This placement ensures that surge voltages resulting from traveling waves are clamped before reaching the transformer's sensitive insulation.

ЁЯФв Key Formulas

Vtotal=Vdischarge+LdidtV_{total} = V_{discharge} + L \frac{di}{dt}VtotalтАЛ=VdischargeтАЛ+LdtdiтАЛ тАФ Voltage experienced by the transformer

BIL>VarresterBIL > V_{arrester}BIL>VarresterтАЛ тАФ Safety condition for transformer insulation

тЪЩя╕П Working Principle

When a surge wave travels along a transmission line, it experiences reflection and refraction at impedance discontinuities, such as at a transformer terminal. If the arrester is far from the transformer, the inductive voltage drop v=Ldidtv = L \frac{di}{dt}v=LdtdiтАЛ across the lead wire increases the effective discharge voltage at the transformer, potentially exceeding its Basic Insulation Level (BIL). By minimizing the lead length, we reduce the additive voltage drop and ensure the transformer is protected by the arrester's protective characteristics.

ЁЯУМ Key Points
  • тЦ╕

    The lightning arrester must be located as close to the equipment being protected as physically possible.

  • тЦ╕

    The lead wire length is critical; excessive length causes high inductive voltage drop during rapid surge currents.

  • тЦ╕

    The purpose is to shunt the surge current to the ground before it stresses the transformer windings.

тЬЕ Advantages
  • тЦ╕

    Prevents transformer winding insulation failure

  • тЦ╕

    Limits transient overvoltages effectively

  • тЦ╕

    Provides a low impedance path for lightning surges

тЭМ Disadvantages / Limitations
  • тЦ╕

    Increased system complexity near the transformer

  • тЦ╕

    Requires regular maintenance and inspection

  • тЦ╕

    Adds capacitive load if not properly designed

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Power transformers in substations

  • тЦ╕

    Distribution transformer protection

  • тЦ╕

    High-voltage transmission line termination

ЁЯУД Additional Information
  • тЦ╕

    Option A is incorrect because the arrester's primary purpose is to protect specific equipment like the transformer, not just the circuit breaker.

  • тЦ╕

    Option B and D are incorrect as increasing the distance allows reflected waves to increase the stress beyond the arrester's protection level.

ЁЯУК Diagram / Illustration
Lightning Arrester PlacementTransmissionLineArresterTransformerGround Connection
тЬЕ

C is correct тАФ The lightning arrester is placed near the transformer to minimize the inductive voltage drop across the connecting leads and ensure the surge voltage remains below the transformer's insulation withstand level.

Core Concepts Used
Click any tag to open in AI Tutor
Surge Protection Basic Insulation Level (BIL) Inductive Voltage Drop Traveling Waves
ЁЯТб EXAM TIP

Always remember that lead inductance LLL acts as a low-pass filter for high-frequency transients; minimize lead length to keep the protection voltage VVV low.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext