Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Main cause of momentary excessive voltages and current are

  1. Lightning

  2. Switching

  3. Short circuit

  4. Resonance

Out of these the most common and most severe causes are

A

1 and 3

B

1 and 2

C

4 and 2

D

3 and 4

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option B

1 and 2

Quick Summary:

Lightning strikes and switching operations are the most common and severe sources of power system transients. Lightning produces high-magnitude external surges, while switching operations cause internal transients due to sudden changes in circuit conditions involving stored electromagnetic energy.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

Lightning strikes and switching operations are the most common and severe sources of power system transients. Lightning produces high-magnitude external surges, while switching operations cause internal transients due to sudden changes in circuit conditions involving stored electromagnetic energy.

ЁЯФв Key Formulas

v=Ldidtv = L \frac{di}{dt}v=LdtdiтАЛ тАФ Voltage induced across an inductor due to rapid current change.

i=Cdvdti = C \frac{dv}{dt}i=CdtdvтАЛ тАФ Current in a capacitor due to rapid voltage change.

тЪЩя╕П Working Principle

Transients occur due to the rapid change in energy state of inductive (LLL) and capacitive (CCC) elements. When a breaker operates (switching), the stored energy 12Li2\frac{1}{2}Li^221тАЛLi2 cannot dissipate instantly, causing a voltage spike v=Ldidtv = L \frac{di}{dt}v=LdtdiтАЛ. Lightning causes high-current surges through atmospheric discharge, creating traveling waves that exceed standard insulation levels.

ЁЯУМ Key Points
  • тЦ╕

    Lightning transients are external and characterized by very high voltage peaks.

  • тЦ╕

    Switching transients are internal and occur during normal operation, faults, or restoration.

  • тЦ╕

    Short circuits cause current surges, but voltage transients are primarily associated with the initiation/clearing of the fault.

  • тЦ╕

    Resonance can lead to high voltage amplification but is generally less frequent than switching.

тЬЕ Advantages
  • тЦ╕

    Identification of transient sources helps in insulation coordination.

  • тЦ╕

    Enables proper design of Surge Protection Devices (SPDs).

тЭМ Disadvantages / Limitations
  • тЦ╕

    Transients can cause insulation failure in transformers and switchgear.

  • тЦ╕

    May lead to nuisance tripping of sensitive electronic equipment.

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Power system protection design.

  • тЦ╕

    Insulation coordination studies.

  • тЦ╕

    Surge arrestor placement optimization.

ЁЯУД Additional Information
  • тЦ╕

    Lightning surges typically have a rise time in microseconds.

  • тЦ╕

    Switching transients are often oscillatory in nature.

  • тЦ╕

    Option A is incorrect because short circuits are not the primary cause of severe voltage surges compared to switching.

  • тЦ╕

    Option C is incorrect as resonance requires specific frequency conditions not as common as switching.

ЁЯУК Diagram / Illustration
Transient Voltage Generationv(t) = L (di/dt)Switching TransientHigh di/dt causes voltage spikes
тЬЕ

B is correct тАФ Lightning and switching are the most frequent and severe causes of electrical transients in power systems.

Core Concepts Used
Click any tag to open in AI Tutor
Power System Transients Insulation Coordination Surge Phenomena
ЁЯТб EXAM TIP

Always distinguish between external transients (Lightning - atmospheric) and internal transients (Switching - operational) for competitive exams.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext