Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Main drawback of overhead system over underground system is

A

Less flexible

B

High charging current

C

Surge problem

D

High initial cost

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option C

Surge problem

Quick Summary:

The primary disadvantage of overhead transmission lines compared to underground cables is their susceptibility to atmospheric disturbances, particularly surges caused by lightning strikes. Because overhead lines are exposed to the atmosphere, they require extensive lightning protection, such as ground wires and surge arresters, to prevent insulation failure.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

The primary disadvantage of overhead transmission lines compared to underground cables is their susceptibility to atmospheric disturbances, particularly surges caused by lightning strikes. Because overhead lines are exposed to the atmosphere, they require extensive lightning protection, such as ground wires and surge arresters, to prevent insulation failure.

ЁЯФв Key Formulas

Vsurge=Zc├ЧIsurgeV_{surge} = Z_c \times I_{surge}VsurgeтАЛ=ZcтАЛ├ЧIsurgeтАЛ тАФ where ZcZ_cZcтАЛ is the surge impedance of the line.

Zc=LCZ_c = \sqrt{\frac{L}{C}}ZcтАЛ=CLтАЛтАЛ тАФ Surge impedance value for overhead lines is typically 400-600 ╬й\Omega╬й.

тЪЩя╕П Working Principle

Overhead lines act as elevated conductors that intercept lightning strikes or experience induced voltages from nearby strikes, creating high-magnitude traveling waves (surges). These waves travel along the line toward terminals, posing a risk of flashover across insulators and damage to transformer windings due to their high dv/dtdv/dtdv/dt. In contrast, underground cables are shielded by the earth's surface, which acts as a natural lightning rod and grounds the potential, inherently protecting them from such surges.

ЁЯУМ Key Points
  • тЦ╕

    Overhead lines are prone to atmospheric voltage surges due to lightning.

  • тЦ╕

    Underground cables have low surge impedance and are naturally protected by the burial depth.

  • тЦ╕

    The surge impedance of underground cables is significantly lower (approx 30-50 ╬й\Omega╬й) than overhead lines.

  • тЦ╕

    Overhead systems are cost-effective but less reliable in areas prone to severe storms.

тЬЕ Advantages
  • тЦ╕

    Lower initial installation cost

  • тЦ╕

    Easy to locate and repair faults

  • тЦ╕

    Higher current-carrying capacity due to air cooling

тЭМ Disadvantages / Limitations
  • тЦ╕

    High vulnerability to lightning surges

  • тЦ╕

    Requires larger clearances and right-of-way

  • тЦ╕

    Affected by wind, ice, and atmospheric pollution

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Long-distance power transmission

  • тЦ╕

    Rural electrification

  • тЦ╕

    High-voltage bulk energy distribution

ЁЯФД Comparison Table
FeatureOverhead SystemUnderground System

Vulnerability to Surges

High

Negligible

Surge Impedance

400-600 ╬й\Omega╬й

30-50 ╬й\Omega╬й

ЁЯУД Additional Information
  • тЦ╕

    Option B (High charging current) is a characteristic disadvantage of underground cables, not overhead lines, due to higher capacitance between conductors and the sheath.

  • тЦ╕

    Option D (High initial cost) is a primary disadvantage of underground systems due to excavation and specialized insulation requirements.

ЁЯУК Diagram / Illustration
Overhead Line Surge MechanismLightning Surge (Traveling Wave)Line ConductorEarth/Ground
тЬЕ

C is correct тАФ The overhead transmission system is highly susceptible to atmospheric surges caused by lightning, necessitating complex protective coordination compared to the inherently protected underground system.

Core Concepts Used
Click any tag to open in AI Tutor
Surge Impedance Atmospheric Overvoltage Power System Protection
ЁЯТб EXAM TIP

In competitive exams, always remember that 'High charging current' is associated with the high capacitance of Underground cables, while 'Surge problem' is synonymous with the high inductance and exposure of Overhead lines.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______