Join 60,000+ competitive exam aspirants
One 200V, 100W bulb is connected in series with the primary of a 200V, 10 kVA transformer. If its secondary is open circuited, then the bulb will have
full brightness.
poor brightness.
little less than full brightness.
more than full brightness.
poor brightness.
Open transformer secondary means near-zero magnetizing current flows through the entire series circuit, drastically reducing power and causing the bulb to glow very dimly.
Open transformer secondary means near-zero magnetizing current flows through the entire series circuit, drastically reducing power and causing the bulb to glow very dimly.
Identify Series Configuration
The bulb and transformer primary are connected in series across the supply voltage. In a series circuit, the same current flows through both the bulb and the transformer primary winding.
Analyze Transformer State
The secondary is open-circuited, meaning there is no load connected. Consequently, the transformer draws only the magnetizing current (no-load current), which is typically 2% to 5% of the rated full-load current.