Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Pilot wire used in

A

Non unit type of protection

B

Unit type of protection

C

Both A and B

D

None of above

Correct Answer

Concept & PrincipleElectricalPower System
Option A

Non unit type of protection

Quick Summary: Pilot wire protection is classified as a unit type protection because it protects a specific zone (the protected section of the transmission line) by comparing the currents entering and leaving that section. It operates on the principle of circulating current or opposed voltage, ensuring the relay trips only for faults within the defined protected zone, ignoring faults outside it.

💡 Explanation

Pilot wire protection is classified as a unit type protection because it protects a specific zone (the protected section of the transmission line) by comparing the currents entering and leaving that section. It operates on the principle of circulating current or opposed voltage, ensuring the relay trips only for faults within the defined protected zone, ignoring faults outside it.

🔢 Key Formulas

Idiff=∣Iin−Iout∣I_{diff} = |I_{in} - I_{out}|Idiff​=∣Iin​−Iout​∣ — Differential current principle

IR=IA−IB=0I_{R} = I_{A} - I_{B} = 0IR​=IA​−IB​=0 — Balanced condition in healthy state

⚙️ Working Principle

The system compares the currents at both ends of the protected line using pilot wires. Under normal or external fault conditions, the vector sum of currents entering and leaving the zone is zero, resulting in no current through the relay. If an internal fault occurs, the balance is disturbed, and the resulting differential current operates the relay.

📌 Key Points
  • ▸

    Pilot wire protection is inherently a unit protection scheme.

  • ▸

    It provides high-speed, selective clearing of faults.

  • ▸

    It is primarily used for feeder and transmission line protection.

  • ▸

    The sensitivity is limited by the length of the pilot wires due to capacitance effects.

✅ Advantages
  • ▸

    Highly selective; operates only for internal faults.

  • ▸

    Fast operating speed.

  • ▸

    Independent of the load current magnitude.

❌ Disadvantages / Limitations
  • ▸

    High installation cost due to auxiliary pilot wires.

  • ▸

    Limited by the maximum length of the pilot circuits.

  • ▸

    Prone to interference and induced voltages.

🛠️ Applications / Uses
  • ▸

    Short transmission lines

  • ▸

    Underground cable feeders

  • ▸

    Busbar protection

🔄 Comparison Table
FeatureNon-UnitUnit

Protection Category

Non-unit (e.g., Distance)

Unit (e.g., Pilot Wire)

📄 Additional Information
  • ▸

    Non-unit types include overcurrent and distance relays, which cover zones that overlap rather than being precisely defined by physical boundaries.

  • ▸

    The term 'Unit Protection' refers to schemes that protect only a specific physical section of the system.

📊 Diagram / Illustration
Pilot Wire Differential ProtectionCT at End ACT at End BPilot WiresRelay
✅

B is correct — Pilot wire protection is a classic example of unit protection because it covers only a specifically defined zone between the current transformers.

Core Concepts Used
Click any tag to open in AI Tutor
Differential Protection Unit Protection Scheme Pilot Wire Communication
💡 EXAM TIP

Always remember that 'Unit Protection' schemes (like Differential or Pilot Wire) have a distinct boundary, whereas 'Non-Unit' schemes (like Distance relays) have zones defined by time-impedance characteristics.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______