Join 60,000+ competitive exam aspirants
Select the option that is appropriate regarding the following two statements labelled Assertion and Reason. Assertion: Piping below the weir can be prevented by providing an impervious floor of sufficient length so that the path of percolation is increased and the exit gradient is decreased. Reason: If the exit gradient is less than a certain critical value, the soil starts boiling and is washed away by percolating water.
Both Assertion and Reason are true, but Reason is not the correct explanation of Assertion.
Assertion is true, but Reason is false.
Both Assertion and Reason are false.
Both Assertion and Reason are true and Reason is the correct explanation of Assertion.
Assertion is true, but Reason is false.
The Assertion is correct because increasing the length of the impervious floor increases the total percolation path length, which effectively reduces the hydraulic gradient at the exit point. The Reason is false because soil boiling and piping occur when the exit gradient exceeds the critical hydraulic gradient (icтАЛ), not when it is less than a certain value.
IS 6966 (Part 1): 1989
The Assertion is correct because increasing the length of the impervious floor increases the total percolation path length, which effectively reduces the hydraulic gradient at the exit point. The Reason is false because soil boiling and piping occur when the exit gradient exceeds the critical hydraulic gradient (icтАЛ), not when it is less than a certain value.
icтАЛ=1+eGтИТ1тАЛ тАФ Critical hydraulic gradient where G is specific gravity and e is void ratio
GeтАЛ=╧А1тАЛтЛЕ╬╗1тАЛтАЛ тАФ Exit gradient at the toe for a flat floor with depth d
As water seeps under the weir, it exerts upward pressure at the downstream end. If the exit gradient (GeтАЛ=dldhтАЛ) becomes equal to or greater than the critical gradient (icтАЛ=1+eGтИТ1тАЛ), the effective stress on soil particles becomes zero, leading to the condition known as 'boiling' or 'quicksand' where particles are lifted and carried away.
Piping is a failure mechanism where percolating water creates a subsurface channel.
The exit gradient is the slope of the hydraulic gradient line at the downstream toe of the impervious floor.
Safe exit gradients are typically kept between 1/5 to 1/7 depending on soil type.
Boiling refers to the state where the upward seepage force equals the submerged weight of the soil.
Increased floor length reduces seepage discharge.
Deep sheet piles at the tail end significantly reduce the exit gradient.
Excessive floor length increases construction costs.
Non-homogeneous soil layers can lead to failure despite design calculations.
Design of barrages and weirs on permeable foundations.
Stabilization of canal regulators.
Standard values: For fine sand, safe exit gradient is often taken as 1/7; for coarse sand, 1/5 to 1/6.
Option B is the correct choice because the Reason statement is factually inverted regarding the safety criteria of the exit gradient.
B is correct тАФ Assertion is true, but Reason is false.
Always remember that for stability against piping, GeтАЛ<icтАЛ. A value of GeтАЛ closer to icтАЛ indicates higher instability, not safety.