In a delta-connected three-phase system, the phase voltage (VphтАЛ) is equal to the line voltage (VLтАЛ). The impedance per phase (ZphтАЛ) is calculated by dividing the phase voltage by the phase current (IphтАЛ), where the phase current is the line current (ILтАЛ) divided by 3тАЛ.
In a delta-connected three-phase system, the phase voltage (VphтАЛ) is equal to the line voltage (VLтАЛ). The impedance per phase (ZphтАЛ) is calculated by dividing the phase voltage by the phase current (IphтАЛ), where the phase current is the line current (ILтАЛ) divided by 3тАЛ.
VphтАЛ=VLтАЛ
IphтАЛ=3тАЛILтАЛтАЛ
ZphтАЛ=IphтАЛVphтАЛтАЛ
For a balanced delta-connected load, the relationship between line and phase values is VLтАЛ=VphтАЛ and ILтАЛ=3тАЛ├ЧIphтАЛ. Given VLтАЛ=300┬аV and ILтАЛ=303тАЛ┬аA, the phase current is IphтАЛ=3тАЛILтАЛтАЛ=3тАЛ303тАЛтАЛ=30┬аA. The impedance is ZphтАЛ=IphтАЛVphтАЛтАЛ=30300тАЛ=10┬а╬й.
In Delta (╬Ф) connection, phase voltage equals line voltage.
In Delta (╬Ф) connection, line current is 3тАЛ times the phase current.
The impedance per phase is the ratio of phase voltage to phase current.
Option B represents the correct calculated value of 10┬а╬й.
Option A (20┬а╬й), C (30┬а╬й), and D (103тАЛ┬а╬й) are incorrect results derived from miscalculating the phase current relationship.
B is correct тАФ The calculated impedance per phase is 10┬а╬й.
Always verify if the connection is Star (Y) or Delta (╬Ф) first, as the current and voltage relationships are inverted between these two configurations.