Join 60,000+ competitive exam aspirants
The direction of rotation of DC motor is reversed by
Reversing supply connection
Adding resistance to the field circuit
Interchanging armature and field connection
Reversing armature connection or field connection
Reversing armature connection or field connection
Remember the torque formula T is proportional to Flux (Phi) times Armature Current (Ia); reversing either one (but not both) reverses the torque and thus the direction of rotation.
Remember the torque formula T is proportional to Flux (Phi) times Armature Current (Ia); reversing either one (but not both) reverses the torque and thus the direction of rotation.
Analyze Torque Direction
The direction of rotation depends on the direction of torque. Torque is generated by the interaction between the field flux and the armature current (T proportional to Flux * Current).
Evaluate Reversal Conditions
Reversing only the field flux (reversing field connection) changes the sign of torque. Reversing only the armature current also changes the sign of torque. If both are reversed, the signs cancel out, keeping the rotation direction the same.
A: Reversing supply reverses both field and armature simultaneously, keeping rotation the same. B: Adding resistance only changes speed, not direction. C: Interchanging both connection types simultaneously cancels the reversal effect.
D is correct because reversing either the armature or the field connection changes the sign of the torque, which flips the direction of rotation.
If both armature and field are reversed at the same time, the motor continues to rotate in the original direction; always look for changing ONLY ONE component to flip direction.