Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

The earth wire should not be of size smaller than

A

10 SWG copper

B

8 SWG copper

C

6 SWG copper

D

4 SWG copper

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option A

10 SWG copper

Quick Summary:

According to the Indian Electricity Rules and BIS standards (IS 3043), the cross-sectional area of a copper earth continuity conductor must not be less than 10 SWG (Standard Wire Gauge). This minimum size ensures that the earth path has sufficient thermal capacity to carry fault currents without melting, allowing protective devices to operate effectively.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

According to the Indian Electricity Rules and BIS standards (IS 3043), the cross-sectional area of a copper earth continuity conductor must not be less than 10 SWG (Standard Wire Gauge). This minimum size ensures that the earth path has sufficient thermal capacity to carry fault currents without melting, allowing protective devices to operate effectively.

ЁЯФв Key Formulas

R=╧БLAR = \rho \frac{L}{A}R=╧БALтАЛ тАФ Resistance of the earth conductor

Q=I2RtQ = I^2 R tQ=I2Rt тАФ Heat generated in the conductor during fault

тЪЩя╕П Working Principle

When a phase-to-earth fault occurs, the earth wire provides a low-impedance return path for the fault current IfI_fIfтАЛ. The resistance of this path is given by Re=╧БlAR_e = \rho \frac{l}{A}ReтАЛ=╧БAlтАЛ. By maintaining a minimum diameter (10 SWG), the cross-sectional area AAA is kept large enough to ensure ReR_eReтАЛ remains low and the wire can withstand the I2RtI^2 RtI2Rt heat generated during the disconnection time of the fuse or circuit breaker.

ЁЯУМ Key Points
  • тЦ╕

    10 SWG copper wire corresponds to approximately 2.5 mm┬▓ to 3.0 mm┬▓ area.

  • тЦ╕

    The earth wire must be mechanically robust to prevent breakage.

  • тЦ╕

    Under fault conditions, the earth wire carries the full short-circuit current.

  • тЦ╕

    Standardization (IS 3043) ensures uniformity in earthing system design across India.

тЬЕ Advantages
  • тЦ╕

    Ensures low impedance return path

  • тЦ╕

    Prevents structural metal parts from reaching dangerous potentials

  • тЦ╕

    Facilitates rapid operation of circuit protective devices

тЭМ Disadvantages / Limitations
  • тЦ╕

    High initial material cost for thick copper conductors

  • тЦ╕

    Susceptible to theft in outdoor environments

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Domestic wiring earthing

  • тЦ╕

    Industrial machinery equipment grounding

  • тЦ╕

    Distribution board earthing

ЁЯУД Additional Information
  • тЦ╕

    SWG (Standard Wire Gauge) is a British standard for wire diameter; lower SWG numbers indicate larger diameters.

  • тЦ╕

    Using a wire smaller than 10 SWG is prohibited because the high fault current could vaporize the conductor before the breaker trips, leading to a fire hazard.

ЁЯУК Diagram / Illustration
Minimum Earth Wire SelectionFault Current Carrying CapacityMinimum Cross-Sectional Area (10 SWG)Heat Energy = I┬▓ R t
тЬЕ

A is correct тАФ The minimum size for a copper earth continuity conductor is specified as 10 SWG to ensure safe thermal and electrical performance during fault conditions.

Core Concepts Used
Click any tag to open in AI Tutor
Earth Continuity Conductor Short Circuit Protection Fault Impedance Indian Electricity Rules
ЁЯТб EXAM TIP

Always remember that lower SWG values correspond to thicker wires, while higher values mean thinner wiresтАФthis is a frequent trap in technical competitive exams.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)