Join 60,000+ competitive exam aspirants
The efficiency of a transformer at a full load of 0.8 p.f. lag is 90%. Its efficiency at a full load of 0.8 p.f. lead will be?
90 %
less than 90 %
more than 90 %
none of the above
90 %
The efficiency of a transformer depends on the output power and the losses (copper and iron). Since losses are independent of the power factor of the load, the efficiency remains identical for the same magnitude of load current regardless of whether the power factor is lagging or leading.
The efficiency of a transformer depends on the output power and the losses (copper and iron). Since losses are independent of the power factor of the load, the efficiency remains identical for the same magnitude of load current regardless of whether the power factor is lagging or leading.
╬╖=Output+LossesOutputтАЛ тАФ General efficiency formula
Losses=PiтАЛ+I22тАЛReqтАЛ тАФ Total losses in a transformer
The efficiency formula is given by ╬╖=V2тАЛI2тАЛcos╧Х+PiтАЛ+I22тАЛReqтАЛV2тАЛI2тАЛcos╧ХтАЛ. Here, PiтАЛ (iron loss) and I22тАЛReqтАЛ (copper loss) are functions of terminal voltage and load current magnitude respectively. Since the magnitude of the load current I2тАЛ is maintained at full load, and the internal losses are independent of the phase angle ╧Х, the efficiency remains invariant with respect to the power factor lag or lead.
Transformer efficiency is solely dependent on the magnitude of the load current and the fixed iron losses.
The phase shift (leading or lagging) changes the reactive power flow but does not alter the real power loss within the transformer windings or core.
At a constant KVA load, the current magnitude I2тАЛ remains constant regardless of the power factor.
Predictable performance under various load conditions
High efficiency for varying power factors
Does not account for frequency variations
Assumes constant terminal voltage
Power transmission networks
Electrical machine testing
The iron loss depends on the operating voltage and frequency, both of which are constant in this scenario.
Option B is incorrect because leading or lagging power factor only influences the voltage regulation of the transformer, not its efficiency.
A is correct тАФ The efficiency is independent of the load power factor as both copper and iron losses depend only on the magnitude of the current and voltage.
Always remember that while Voltage Regulation is heavily dependent on power factor, Efficiency is purely a function of Real Power (Watts) and Losses.