Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

The minimum clearance required between the live conductors and maintenance operator is called

A

Ground clearance

B

Phase clearance

C

Sectional clearance

D

None of above

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option C

Sectional clearance

Quick Summary:

Sectional clearance is the minimum safety distance provided in a substation between live conductors and the ground or structures where maintenance personnel may be working. This clearance ensures that a person does not experience an electric discharge or flashover while performing routine maintenance or inspection tasks.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

Sectional clearance is the minimum safety distance provided in a substation between live conductors and the ground or structures where maintenance personnel may be working. This clearance ensures that a person does not experience an electric discharge or flashover while performing routine maintenance or inspection tasks.

ЁЯФв Key Formulas

dminтИЭVd_{min} \propto VdminтАЛтИЭV

E=VdE = \frac{V}{d}E=dVтАЛ

тЪЩя╕П Working Principle

The principle relies on the Dielectric Strength of air. Under normal operating voltages, air acts as an insulator. If the physical distance between a live part and a person is reduced below the sectional clearance, the electric field intensity can exceed the breakdown strength of air (EbreakdownтЙИ30kV/cmE_{breakdown} \approx 30 kV/cmEbreakdownтАЛтЙИ30kV/cm), leading to an arc or flashover.

ЁЯУМ Key Points
  • тЦ╕

    Sectional clearance is specific to substation layout and safety codes (IS 3072).

  • тЦ╕

    It depends on the nominal system voltage level.

  • тЦ╕

    It differs from ground clearance, which is the height of the lowest conductor from the ground level.

  • тЦ╕

    Safety is maintained by ensuring d>dmind > d_{min}d>dminтАЛ where VVV is the phase-to-ground voltage.

тЬЕ Advantages
  • тЦ╕

    Prevents accidental electrocution during maintenance.

  • тЦ╕

    Ensures compliance with electrical safety standards (e.g., CEA regulations in India).

тЭМ Disadvantages / Limitations
  • тЦ╕

    Higher clearance requirements increase the physical footprint of the substation.

  • тЦ╕

    Increased land costs for larger installations.

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    High Voltage Substations (HV and EHV)

  • тЦ╕

    Switchyards

  • тЦ╕

    Power Transformers maintenance zones

ЁЯУД Additional Information
  • тЦ╕

    For a 33 kV substation, the minimum sectional clearance is typically defined to be around 2.8 meters.

  • тЦ╕

    Ground clearance refers to the height of the conductor from the ground to prevent contact with passersby, whereas sectional clearance is specifically for operators within the substation.

  • тЦ╕

    Phase clearance refers to the distance between two phases of the conductors.

ЁЯУК Diagram / Illustration
Sectional Clearance GeometryLive BusbarDOperator PositionD = Minimum Sectional Clearance
тЬЕ

C is correct тАФ Sectional clearance is the vital safety gap required between energized equipment and maintenance staff to prevent flashover.

Core Concepts Used
Click any tag to open in AI Tutor
Electrical Safety Substation Design Dielectric Strength of Air
ЁЯТб EXAM TIP

Always remember: 'Sectional' is for the person (operator), 'Phase' is for the conductors, and 'Ground' is for vertical clearance above terrain.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______