The power factor of ac circuit lies between
and 1
and 1
and -1
None of the above
and 1
The power factor (p.f.) of an AC circuit is defined as the cosine of the phase angle between the voltage and current phasors. Since the phase difference ╧Х in a passive circuit varies from тИТ90┬░ to +90┬░, the value of cos(╧Х) remains bounded within the interval [0,1].
The power factor (p.f.) of an AC circuit is defined as the cosine of the phase angle between the voltage and current phasors. Since the phase difference ╧Х in a passive circuit varies from тИТ90┬░ to +90┬░, the value of cos(╧Х) remains bounded within the interval [0,1].
p.f.=cos(╧Х)=SPтАЛ тАФ Basic definition of power factor as a ratio of real power to apparent power
╧Х=тИаVтИТтИаI тАФ Phase angle between voltage and current phasors
In an AC circuit, the power factor is given by the ratio of real power to apparent power. Because real power P=VIcos(╧Х) can never exceed the apparent power S=VI in passive components, the ratio SPтАЛ=cos(╧Х) must fall between 0 (purely reactive) and 1 (purely resistive).
A power factor of 1 is termed 'unity', representing a purely resistive circuit.
A power factor of 0 occurs in purely inductive or capacitive circuits where the phase shift is 90┬░.
Lagging power factor is associated with inductive loads, while leading is associated with capacitive loads.
The power factor is dimensionless.
High power factor reduces I2R losses in transmission lines.
Higher power factor improves voltage regulation and system efficiency.
Low power factor increases the current required to deliver the same real power, leading to larger cable sizing.
Utilities impose penalties for low power factor as it increases the kVA demand on the system.
Industrial motor drives and transformer loading optimization.
Power factor correction capacitor banks in distribution networks.
Values outside the range 0 to 1 would imply the generation of real power by a passive component, which violates the law of conservation of energy.
Option B (-1 to 1) is mathematically incorrect because the cosine function for phase angles between тИТ╧А/2 and ╧А/2 is always non-negative.
A is correct тАФ The power factor is defined as the cosine of the phase angle difference between voltage and current, which mathematically ranges from 0 to 1.
Always remember that in power systems, we prioritize maintaining a 'lagging' p.f. close to unity, as active power consumption is required for most industrial inductive loads like induction motors.