Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Transformer oil acidity should be

A

0.4 mg KOH/g

B

0.5 mg KOH/g

C

0.6 mg KOH/g

D

0.7 mg KOH/g

Correct Answer

Concept & PrincipleElectricalPower System
Option A

0.4 mg KOH/g

Quick Summary: Transformer oil acidity is a critical metric used to assess the degradation or 'aging' of insulating oil due to oxidation. The acidity level, measured as mg of Potassium Hydroxide (KOH) required to neutralize 1 gram of oil, must not exceed 0.4 mg KOH/g for operational safety.

💡 Explanation

Transformer oil acidity is a critical metric used to assess the degradation or 'aging' of insulating oil due to oxidation. The acidity level, measured as mg of Potassium Hydroxide (KOH) required to neutralize 1 gram of oil, must not exceed 0.4 mg KOH/g for operational safety.

🔢 Key Formulas

Acidity=mKOHmoilAcidity = \frac{m_{KOH}}{m_{oil}}Acidity=moil​mKOH​​ — Represents the Neutralization Number in mg KOH/g

⚙️ Working Principle

As a transformer operates, the oil is exposed to high temperatures and contact with oxygen, leading to the formation of organic acids, sludge, and water. These acidic by-products accelerate the deterioration of solid paper insulation and promote corrosion of metallic parts. Maintaining acidity below 0.4 mg KOH/g ensures the insulating properties remain within acceptable limits for the long-term reliability of the transformer.

📌 Key Points
  • ▸

    Acidity increases as transformer oil oxidizes over time.

  • ▸

    Higher acidity levels reduce the dielectric strength of the insulating system.

  • ▸

    Acidic oil accelerates the degradation of cellulose paper insulation.

  • ▸

    Periodic testing is required as part of the preventive maintenance schedule (IS 1866).

✅ Advantages
  • ▸

    Prevents internal corrosion of transformer tanks and components.

  • ▸

    Extends the lifespan of the solid insulation (cellulose paper).

  • ▸

    Provides an early warning indicator for oil replacement or regeneration.

❌ Disadvantages / Limitations
  • ▸

    Does not provide information about moisture content directly.

  • ▸

    Testing requires laboratory titration, which can be time-consuming.

🛠️ Applications / Uses
  • ▸

    Routine condition monitoring of Power Transformers.

  • ▸

    Acceptance testing for new transformer oil.

  • ▸

    Diagnostic analysis for failed or overheated transformers.

📄 Additional Information
  • ▸

    According to IS:1866, the maximum permissible acidity for in-service transformer oil is generally 0.4 mg KOH/g. Values exceeding this threshold indicate the oil should be reclaimed or replaced.

  • ▸

    Options B, C, and D represent values that indicate higher levels of oil degradation, making them unsuitable as standard limits for healthy insulation.

📊 Diagram / Illustration
Acidity DefinitionMass of KOH (mg)Mass of Oil (g)Limit: 0.4 mg KOH/g
✅

A is correct — The maximum permissible acidity limit for mineral insulating oil in transformers is typically 0.4 mg KOH/g to prevent corrosion and paper deterioration.

Core Concepts Used
Click any tag to open in AI Tutor
Oil Oxidation Neutralization Number Insulation Aging
💡 EXAM TIP

Always remember that transformer oil acts as both an electrical insulator and a cooling medium; its chemical stability is just as important as its dielectric strength.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext