Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

What is standard dielectric strength of oil?

A

35KV

B

50KV 40KV

C

40KV 50KV

D

30KV

Correct Answer

Concept & PrincipleElectricalPower System
Option D

30KV

Quick Summary: The standard dielectric strength of transformer oil, also known as the breakdown voltage, is officially specified as 30 kV (rms) for a 2.5 mm gap using standard spherical electrodes according to IS 335 standards. This value serves as the minimum threshold to ensure the oil can effectively act as an insulator and coolant within power transformers.

💡 Explanation

The standard dielectric strength of transformer oil, also known as the breakdown voltage, is officially specified as 30 kV (rms) for a 2.5 mm gap using standard spherical electrodes according to IS 335 standards. This value serves as the minimum threshold to ensure the oil can effectively act as an insulator and coolant within power transformers.

🔢 Key Formulas

E=VdE = \frac{V}{d}E=dV​ — where EEE is dielectric strength, VVV is breakdown voltage, and ddd is electrode gap distance.

⚙️ Working Principle

The dielectric strength of oil is primarily governed by its purity, specifically the presence of moisture, dissolved gases, and suspended particles. Under an applied electric field, these impurities align to form conductive bridges across the gap, leading to electrical breakdown. Maintaining the dielectric strength above 30 kV ensures that the insulation system remains robust against transient overvoltages and steady-state operating stress.

📌 Key Points
  • ▸

    The standard test uses a gap of 2.5 mm between two 12.5-13 mm diameter spherical electrodes.

  • ▸

    Dielectric strength is measured using an oil testing set following IS 335 specifications.

  • ▸

    Presence of water even in parts per million (ppm) significantly reduces the dielectric strength.

  • ▸

    Oil is used for both internal insulation and heat dissipation in transformers.

✅ Advantages
  • ▸

    High insulation resistance

  • ▸

    Effective cooling medium

  • ▸

    Oxidation stability

❌ Disadvantages / Limitations
  • ▸

    Flammable nature of mineral oil

  • ▸

    Sensitive to moisture contamination

  • ▸

    Requires periodic testing and maintenance

🛠️ Applications / Uses
  • ▸

    Power transformers

  • ▸

    Distribution transformers

  • ▸

    Circuit breakers (OCB)

  • ▸

    Tap changers

📄 Additional Information
  • ▸

    The 30 kV value is the minimum limit; healthy oil typically shows values between 40 kV to 60 kV depending on treatment.

  • ▸

    Oil with a dielectric strength below 30 kV indicates significant contamination, necessitating filtration or replacement.

📊 Diagram / Illustration
Dielectric Strength TestBreakdown Voltage (V)Gap Distance (d = 2.5 mm)Standard: 30 kV
✅

D is correct — The standard dielectric strength for fresh transformer oil is 30 kV when measured across a 2.5 mm gap.

Core Concepts Used
Click any tag to open in AI Tutor
Dielectric Strength Transformer Insulation Breakdown Voltage IS 335 Standards
💡 EXAM TIP

Always remember that dielectric strength is inversely proportional to the level of moisture and impurities; a drop below 30 kV is a primary trigger for oil filtration in maintenance scheduling.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext