What is the phase spread of winding in 1-phase Induction motor?
60
90
120
180
180
In a 1-phase induction motor, the phase spread of the main winding is 180 electrical degrees. This signifies that the winding occupies the full span of a pole pitch under which the magnetic flux is directed in a single polarity.
In a 1-phase induction motor, the phase spread of the main winding is 180 electrical degrees. This signifies that the winding occupies the full span of a pole pitch under which the magnetic flux is directed in a single polarity.
1 Pole Pitch=180° (electrical) — Relationship between spatial distribution and electrical degrees
In a single-phase machine, the stator winding is distributed over 180 electrical degrees per pole. Unlike polyphase machines where the winding is distributed over a fraction of the pole pitch (e.g., 60 or 120 degrees) to create a rotating magnetic field, the 1-phase winding covers the entire 180-degree pole pitch, which produces a pulsating (standing) magnetic field.
A 180° phase spread implies the winding covers the entire pole pitch.
Single-phase windings produce a pulsating field rather than a rotating field.
Polyphase motors typically use 60° or 120° phase spreads to achieve balanced rotating flux.
Electrical degrees are related to mechanical degrees by the factor P/2.
Simple construction
Suitable for low power domestic applications
Not self-starting
Requires auxiliary winding or centrifugal switch for starting torque
Ceiling fans
Refrigerator compressors
Phase spread is the range of degrees (electrical) over which the coils of a single phase are distributed.
Option A (60) is the typical phase spread for 3-phase induction motor windings.
Option B (90) is used in specific split-phase or capacitor-start motor configurations for the auxiliary winding phase shift.
D is correct — The phase spread of a single-phase winding is 180 electrical degrees, covering the entire pole pitch.
Remember that 3-phase windings are almost exclusively distributed over 60° phase spreads to optimize the distribution factor (Kd), whereas single-phase motors utilize the full 180° for the main winding.