Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalMachine
PrevNext

When the rotor reached ___________ (rated speed), the centrifugal switch (CS) connected in series with starting winding will disconnect the ___________ from 1-Φ supply.

A

20-30 % speed, auxiliary winding

B

40-50 % speed, main winding

C

70-80 % speed, auxiliary winding

D

50 % speed, main winding

Correct Answer

⚙️ TE • Technical Functional MemoryElectricalMachine
Option C

70-80 % speed,     auxiliary winding

Quick Summary:

Quick Trick: Remember the 75% rule for single-phase motors: the switch trips near normal operating speed (~70-80%) to disconnect the auxiliary (starting) winding once main torque takes over.

🧩REReasoning SolutionFunctional Memory
⚡ Quick Shortcut Trick

Remember the 75% rule for single-phase motors: the switch trips near normal operating speed (~70-80%) to disconnect the auxiliary (starting) winding once main torque takes over.

📊 Diagram / Illustration
Starting Phase0% to 70% SpeedCS TriggersAt 70-80% SpeedAuxOFFCircuit Connection:CS is in SERIES with Auxiliary Winding (disconnects it at70-80% speed)Main Winding remains permanently connected across 1-Phasesupply
🧩 Logic Steps
1

Identify the Role of the Auxiliary Winding

A single-phase induction motor is not self-starting. An auxiliary (starting) winding creates the initial rotating magnetic field to produce starting torque.

2

Identify the Function of the Centrifugal Switch

Once the motor accelerates near rated speed, the auxiliary winding is no longer needed and would overheat if left energized. The centrifugal switch (CS) is connected in series with the auxiliary winding to open its circuit.

3

Determine the Threshold Speed Range

Standard design practice dictates that the centrifugal switch operates open at approximately 70% to 80% of rated synchronous speed.

🚫 Why Other Options Are Wrong

A: 20-30% speed is too low to disconnect the starting winding as sufficient main torque hasn't developed; B: Main winding must remain connected for continuous operation; D: Main winding is never disconnected by the centrifugal switch.

✅

C is correct because the centrifugal switch disconnects the auxiliary winding once the rotor reaches 70-80% of rated speed, allowing the motor to run solely on the main winding.

Core Concepts Used
Click any tag to open in AI Tutor
Centrifugal Switch Operation Single-Phase Induction Motor Starting Methods Auxiliary vs Main Winding Functions
💡 EXAM TIP

Always remember: Main winding stays connected indefinitely; starting/auxiliary winding gets disconnected by the centrifugal switch between 75% to 80% speed.

Related Questions

ElectricalMachine
In the design of single-phase induction motor. The Length of air gap is given by
ElectricalMachine
In the design of single-phase induction motor. The length of a mean turn of each coil per pole,
ElectricalMachine
In the design of single-phase induction motor. The flux density in the stator core is given by
ElectricalMachine
In the design of single-phase induction motor. The maximum flux density in stator core is ____________ for and the normal range is _________
ElectricalMachine
In the design of single-phase induction motor. The flux density in stator teeth is given by