Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Which is called rated burden of relay?

A

Voltage

B

Ampere

C

Power consumption

D

None of above

Correct Answer

Concept & PrincipleElectricalPower System
Option C

Power consumption

Quick Summary: The rated burden of a relay is defined as the power consumed by the relay coil at its rated current or voltage. It is expressed in Volt-Amperes (VA) for AC circuits to quantify the load imposed by the relay on the instrument transformers (CTs or PTs) supplying it.

💡 Explanation

The rated burden of a relay is defined as the power consumed by the relay coil at its rated current or voltage. It is expressed in Volt-Amperes (VA) for AC circuits to quantify the load imposed by the relay on the instrument transformers (CTs or PTs) supplying it.

🔢 Key Formulas

S=V⋅IS = V \cdot IS=V⋅I — Fundamental Power formula for burden

SCT=Irated2⋅ZrelayS_{CT} = I_{rated}^2 \cdot Z_{relay}SCT​=Irated2​⋅Zrelay​ — Burden for overcurrent relays

⚙️ Working Principle

A protective relay is connected to the secondary of a Current Transformer (CT) or Potential Transformer (PT). The relay coil acts as an impedance ZZZ. The power consumed by this impedance is the burden, given by S=I2ZS = I^2 ZS=I2Z for overcurrent relays or S=V2/ZS = V^2 / ZS=V2/Z for overvoltage relays. Ensuring the relay burden remains within the rated capacity of the CT/PT is critical to avoid saturation and ensure measurement accuracy.

📌 Key Points
  • ▸

    Burden is expressed in VA for AC and Watts for DC.

  • ▸

    A lower relay burden is preferred to increase the accuracy of instrument transformers.

  • ▸

    Excessive burden causes CT saturation and reduces the relay's sensitivity.

  • ▸

    It is measured at a specified frequency (usually 50 Hz in India).

✅ Advantages
  • ▸

    Helps in selecting appropriate CT/PT ratings.

  • ▸

    Ensures compatibility between secondary equipment and instrument transformers.

❌ Disadvantages / Limitations
  • ▸

    Higher relay burden increases the heat dissipation in the relay coil.

  • ▸

    High burden requires larger, costlier instrument transformers.

🛠️ Applications / Uses
  • ▸

    Switchgear protection design

  • ▸

    Coordination of relays in power systems

📄 Additional Information
  • ▸

    Standard burden values are often specified by manufacturers at rated current (e.g., 1A or 5A).

  • ▸

    Option A (Voltage) and Option B (Ampere) are independent parameters that, when multiplied, constitute the power (VA).

📊 Diagram / Illustration
Rated Burden (S)S = I² × ZUnit: Volt-Ampere (VA)
✅

C is correct — Rated burden is the power consumption of the relay coil, expressed in Volt-Amperes (VA).

Core Concepts Used
Click any tag to open in AI Tutor
Instrument Transformer Loading Relay Impedance Volt-Ampere (VA) Rating
💡 EXAM TIP

Always ensure the total connected burden of all relays on a CT secondary circuit does not exceed the CT's rated burden to prevent accuracy class degradation.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext