Join 60,000+ competitive exam aspirants
Which motor cannot be started on no load?
shunt motors
series motors
cumulative compound motors
both B and C
series motors
A DC series motor must never be started on no-load because its speed becomes dangerously high and can cause the motor to destroy itself due to centrifugal force. At no-load, the armature current IaтАЛ is extremely small, and since flux ╬ж is directly proportional to IaтАЛ in a series motor, the flux approaches nearly zero, leading to an infinite speed.
A DC series motor must never be started on no-load because its speed becomes dangerously high and can cause the motor to destroy itself due to centrifugal force. At no-load, the armature current IaтАЛ is extremely small, and since flux ╬ж is directly proportional to IaтАЛ in a series motor, the flux approaches nearly zero, leading to an infinite speed.
NтИЭ╬жEbтАЛтАЛ тАФ Speed is inversely proportional to the flux
╬жтИЭIaтАЛ тАФ Flux is proportional to the armature current in series field
In a DC series motor, the field winding is connected in series with the armature. The torque is given by TтИЭ╬жIaтАЛ and ╬жтИЭIaтАЛ. Therefore, TтИЭIa2тАЛ. At no-load, IaтАЛ is very low, making ╬ж very low. Since the back EMF equation is EbтАЛ=60AP╬жZNтАЛ, the speed N is inversely proportional to flux (NтИЭ╬жEbтАЛтАЛ). As ╬жтЖТ0, NтЖТтИЮ.
DC series motors have high starting torque.
The series field winding has few turns of thick wire.
Operation at no-load leads to 'runaway' condition.
Always start series motors with some mechanical load connected.
High starting torque
Compact design for high power output
Unstable speed at light loads
Cannot be used where load might be disconnected (like belt drives)
Electric traction (trains)
Cranes and hoists
Shunt motors have a nearly constant flux, which makes them self-limiting in speed at no-load.
Cumulative compound motors also possess a shunt winding, which prevents the flux from reaching zero, unlike pure series motors.
B is correct тАФ DC series motors exhibit runaway speed characteristics at no-load because the field flux drops to near zero as the armature current decreases.
Always remember: 'Shunt for constant speed, Series for high starting torque'тАФand never disconnect the load from a Series motor while it is energized.