Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Which of the following is non unit type of protection in transmission line?

A

Pilot wire differential protection

B

Phase comparison

C

Carrier current protection

D

Current graded over current protection

Correct Answer

Concept & PrincipleElectricalPower System
Option D

Current graded over current protection

Quick Summary: A non-unit type of protection is one where the protection zone is not restricted to a specific section of the transmission line and does not compare inputs at both ends of the protected zone. In 'Current Graded Overcurrent Protection', the relay coordination depends on time settings or current magnitude settings which cover overlapping segments of the system, rather than isolating only one specific zone.

💡 Explanation

A non-unit type of protection is one where the protection zone is not restricted to a specific section of the transmission line and does not compare inputs at both ends of the protected zone. In 'Current Graded Overcurrent Protection', the relay coordination depends on time settings or current magnitude settings which cover overlapping segments of the system, rather than isolating only one specific zone.

🔢 Key Formulas

Ttrip=Trelay+TcbT_{trip} = T_{relay} + T_{cb}Ttrip​=Trelay​+Tcb​ — Total time taken for fault clearance

Ipickup>Iload(max)I_{pickup} > I_{load(max)}Ipickup​>Iload(max)​ — Fundamental condition for overcurrent protection

⚙️ Working Principle

The principle relies on time-grading or current-grading. By setting different relays with different pickup times or current thresholds, the relay closest to the fault is designed to trip first. Since these zones overlap into adjacent sections, they are classified as non-unit systems because they do not exclusively respond to faults within a fixed boundary.

📌 Key Points
  • ▸

    Unit protection responds only to faults within the protected zone.

  • ▸

    Non-unit protection has no fixed zone boundary and provides back-up for adjacent sections.

  • ▸

    Pilot wire, phase comparison, and carrier current are all types of unit protection.

  • ▸

    Graded protection requires coordination studies to prevent maloperation.

✅ Advantages
  • ▸

    Simple construction

  • ▸

    Economical and reliable for primary protection

  • ▸

    Provides inherent backup protection for downstream zones

❌ Disadvantages / Limitations
  • ▸

    Coordination becomes difficult in complex networks

  • ▸

    Slower fault clearance compared to unit protection

  • ▸

    Sensitivity decreases as number of cascaded sections increases

🛠️ Applications / Uses
  • ▸

    Radial distribution feeders

  • ▸

    Back-up protection for transmission lines

  • ▸

    Distribution network protection

🔄 Comparison Table
FeatureUnit ProtectionNon-Unit Protection

Zone Definition

Strictly defined (Unit)

Undefined/Overlapping (Non-Unit)

📄 Additional Information
  • ▸

    Unit schemes like Differential Protection use the principle of Kirchoff's Current Law (Iin−Iout=IfaultI_{in} - I_{out} = I_{fault}Iin​−Iout​=Ifault​), making them highly selective.

  • ▸

    Carrier current protection uses high-frequency signals over the power line to compare conditions at both ends, ensuring unit-style selectivity.

📊 Diagram / Illustration
Protection ClassificationUnit ProtectionNon-Unit ProtectionDifferential, Pilot WireOvercurrent, Distance
✅

D is correct — Current graded overcurrent protection is a non-unit type of protection as it relies on time and current settings that overlap into adjacent system sections.

Core Concepts Used
Click any tag to open in AI Tutor
Relay Coordination Selectivity Back-up Protection
💡 EXAM TIP

Always remember: 'Unit' = 'Selective/Differential' (comparing boundaries), 'Non-Unit' = 'Graded' (relying on time/current magnitude).

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______