Join 60,000+ competitive exam aspirants
Which of the following is true for a single-phase induction motor?
high starting torque
low starting torque
average starting torque
zero starting torque
zero starting torque
A standard single-phase induction motor is not self-starting because its stator winding produces a pulsating magnetic field rather than a rotating magnetic field. Consequently, the net starting torque is zero, as the forward and backward rotating fields cancel each other out at standstill.
A standard single-phase induction motor is not self-starting because its stator winding produces a pulsating magnetic field rather than a rotating magnetic field. Consequently, the net starting torque is zero, as the forward and backward rotating fields cancel each other out at standstill.
TnetтАЛ=TfтАЛ+TbтАЛ
TstartтАЛ=TfтАЛ+(тИТTbтАЛ)=0 (at standstill)
According to the Double-Revolving Field Theory, the pulsating flux produced by a single-phase AC current can be resolved into two equal and opposite rotating components, each of magnitude 2╬жmтАЛтАЛ. Since these fields rotate at synchronous speed in opposite directions, they generate equal and opposite torques at NrтАЛ=0, resulting in zero net torque. To initiate rotation, an auxiliary phase-shifting device (capacitor or inductive winding) is required to create an elliptical rotating field.
Single-phase motors lack a inherent rotating magnetic field.
The stator produces a pulsating (oscillating) magnetic field.
External starting methods like capacitor-start or split-phase are required.
Once started, the motor produces torque due to rotor slip creating an asymmetric magnetic field.
Simple construction
Low maintenance cost
Suitable for small home appliances
Not self-starting
Lower power factor compared to 3-phase motors
Higher vibration and noise
Fans and blowers
Small centrifugal pumps
Domestic refrigeration compressors
Option A (high starting torque) is typically associated with Capacitor-Start motors after the centrifugal switch is activated or DC Series motors.
Option B (low starting torque) is a general characteristic of induction motors before starting aids are employed.
D is correct тАФ A single-phase induction motor is not inherently self-starting because the pulsating magnetic field produced by the stator results in a net torque of zero at standstill.
Always remember that for a motor to be self-starting, the phase difference between stator currents must be non-zero to create a Rotating Magnetic Field (RMF).