Join 60,000+ competitive exam aspirants
Which section of reinfoced concrete strcture typically does NOT experience moment reduction due to moment redistribution?
Beam
continuous slab
Flat slabs
Slab
continuous slab
Moment redistribution is a structural behavior allowed in reinforced concrete to permit the shedding of peak elastic moments to less heavily loaded sections, requiring significant ductility. Continuous slabs are generally governed by serviceability criteria (deflection and cracking) rather than ultimate strength ductility, and as such, IS 456:2000 does not permit moment redistribution for such members.
IS 456:2000 Cl. 22.7
Moment redistribution is a structural behavior allowed in reinforced concrete to permit the shedding of peak elastic moments to less heavily loaded sections, requiring significant ductility. Continuous slabs are generally governed by serviceability criteria (deflection and cracking) rather than ultimate strength ductility, and as such, IS 456:2000 does not permit moment redistribution for such members.
╬┤rтАЛтЙд30% тАФ Maximum allowable reduction for elastic moment
dxuтАЛтАЛтЙе0.5 тАФ Condition for redistribution limiting
Moment redistribution relies on the formation of plastic hinges in over-reinforced or balanced-to-under-reinforced sections. When a section reaches its ultimate moment capacity MuтАЛ, rotation continues at constant moment until adjacent sections also reach capacity. This redistribution process is restricted by codes to maintain safety against brittle failure.
Redistribution is valid for frames and continuous beams where plastic hinges can form.
Required ductility is ensured by limiting the depth of neutral axis dxuтАЛтАЛ at the critical sections.
Continuous slabs are explicitly excluded from this provision due to the necessity of maintaining serviceability limits over strength.
Redistribution allows for a more economical design by balancing the reinforcement demand.
Reduces peak reinforcement congestion at supports.
Optimizes material usage by balancing moments across the span.
Increases potential for excessive crack widths if not carefully managed.
Requires high ductility which limits steel grade usage.
Indeterminate multi-storey building frames.
Continuous reinforced concrete beams.
IS 456 Clause 22.7.1 clearly states that redistribution of moments is permitted for beams and frames, but explicitly excludes continuous slabs.
The wrong options (A, C, D) are generally considered structures where redistribution could be mathematically modeled or allowed under specific frame analysis conditions, unlike the standard continuous slab.
B is correct тАФ Continuous slabs are excluded from the provisions of moment redistribution according to IS 456:2000.
Always verify if a structural element is strength-governed (where redistribution is useful) or serviceability-governed (where redistribution is usually prohibited) before applying moment modification.