Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

While closing the circuit, which device opened first?

A

Circuit breaker

B

Isolator

C

Earthing switch

D

None of above

Correct Answer

Concept & PrincipleElectricalPower System
Option C

Earthing switch

Quick Summary: To ensure electrical safety during maintenance, the Earthing Switch must be opened first when energizing a circuit that has been grounded. This prevents the intentional short-circuit path to ground from being active while the primary circuit components are being engaged.

💡 Explanation

To ensure electrical safety during maintenance, the Earthing Switch must be opened first when energizing a circuit that has been grounded. This prevents the intentional short-circuit path to ground from being active while the primary circuit components are being engaged.

🔢 Key Formulas

Ifault=VphaseZgroundI_{fault} = \frac{V_{phase}}{Z_{ground}}Ifault​=Zground​Vphase​​ — represents the fault current if the circuit is closed while grounded

⚙️ Working Principle

The switching sequence follows a strict 'Last In, First Out' (LIFO) protocol regarding grounds. When closing a circuit (energizing): 1. Open the Earthing Switch (removes ground path). 2. Close the Isolator (establishes physical connection). 3. Close the Circuit Breaker (establishes current flow). This sequence avoids fault conditions caused by energizing a grounded circuit.

📌 Key Points
  • ▸

    Switchgear operation sequences are safety-interlocked to prevent equipment damage.

  • ▸

    The earthing switch provides a metallic path to earth for safe maintenance.

  • ▸

    Energizing a circuit with an active ground leads to an immediate short-circuit fault.

  • ▸

    Isolators are for visible disconnection and are not designed to break load current.

✅ Advantages
  • ▸

    Prevents personnel electrocution during maintenance

  • ▸

    Protects primary switchgear from short-circuit damage during startup

❌ Disadvantages / Limitations
  • ▸

    Requires complex mechanical or electrical interlocking systems

  • ▸

    Human error in sequence leads to catastrophic failure

🛠️ Applications / Uses
  • ▸

    High Voltage Substations

  • ▸

    Switchgear panels for Industrial Power Distribution

  • ▸

    Transmission lines maintenance

📄 Additional Information
  • ▸

    Interlocks (Key or Electrical) are mandatory to enforce this specific switching sequence.

  • ▸

    Circuit breaker is the only device rated to interrupt fault currents; isolators and earthing switches are not.

📊 Diagram / Illustration
Energization Sequence1. Open Earth2. Close Isolator3. Close CB
✅

C is correct — The earthing switch must be opened first to remove the intentional ground before the circuit is energized.

Core Concepts Used
Click any tag to open in AI Tutor
Switching Sequence Interlocking Systems Fault Protection
💡 EXAM TIP

Always remember: 'Open Earth, Close Power' during energization; 'Open Power, Close Earth' during de-energization for maintenance.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______