Wind turbine extracts maximum power from wind, when downstream wind speed reduces to
One third of upstream wind speed
Half of upstream wind speed
Two third of upstream wind speed
Zero
One third of upstream wind speed
According to Betz's Law, a wind turbine extracts maximum power when the downstream wind speed (v2тАЛ) is reduced to exactly one-third of the upstream wind speed (v1тАЛ). This condition corresponds to the maximum power coefficient (CpтАЛ) of 2716тАЛ, which represents the theoretical limit of energy extraction.
According to Betz's Law, a wind turbine extracts maximum power when the downstream wind speed (v2тАЛ) is reduced to exactly one-third of the upstream wind speed (v1тАЛ). This condition corresponds to the maximum power coefficient (CpтАЛ) of 2716тАЛ, which represents the theoretical limit of energy extraction.
v2тАЛ=31тАЛv1тАЛ тАФ Optimum downstream velocity
CpтАЛ=21тАЛ╧БAv13тАЛPturbineтАЛтАЛ=2716тАЛ тАФ Maximum Power Coefficient (Betz Limit)
The principle relies on the conservation of mass and momentum in an actuator disc model. As wind passes through the turbine, it loses kinetic energy, resulting in a velocity decrease. To maximize energy extraction, the turbine rotor must exert a force that decelerates the air stream to v2тАЛ=31тАЛv1тАЛ, ensuring the maximum pressure drop across the disc.
Betz's Law applies to an ideal actuator disc model of a wind turbine.
The upstream wind speed is denoted as v1тАЛ, while downstream is v2тАЛ.
Maximum efficiency occurs at CpтАЛ=0.593.
If v2тАЛ=0, the air would stop completely, which is physically impossible as no flow would pass through the turbine.
Provides a theoretical benchmark for turbine design
Helps in calculating the maximum possible yield from wind sites
Does not account for real-world losses like drag, wake rotation, or finite blade numbers
Requires complex flow modeling for practical application
Wind turbine blade aerodynamics
Performance analysis of HAWT (Horizontal Axis Wind Turbines)
Option B (Half) is often confused due to the mean velocity assumption, but it results in lower power output.
Option D (Zero) would imply all kinetic energy is removed, which would block air flow, resulting in zero power output.
A is correct тАФ The turbine extracts maximum power when the downstream wind speed is reduced to one-third of the upstream wind speed.
Remember that CpтАЛ=0.593 is the universal Betz limit; any turbine design that claims higher efficiency likely calculates it based on a different reference area or includes non-standard parameters.