A 3-phase transmission line conductors were arranged in horizontal spacing, with d as the distance between adjacent conductors. If these conductors are rearranged to form an equilateral triangle with sides equal d, then the
Capacitance and the inductance will increase
Capacitance will increase and the inductance will decrease
Capacitance and the inductance will remain the same
Capacitance will decrease and the inductance will increase
Capacitance will decrease and the inductance will increase
In a horizontal configuration, the Geometric Mean Distance (GMD) is calculated as 3d├Чd├Ч2dтАЛ=32тАЛdтЙИ1.26d. In an equilateral triangle configuration, the GMD is simply d. Since GMD is reduced from 1.26d to d, the inductance L decreases and the capacitance C increases.
In a horizontal configuration, the Geometric Mean Distance (GMD) is calculated as 3d├Чd├Ч2dтАЛ=32тАЛdтЙИ1.26d. In an equilateral triangle configuration, the GMD is simply d. Since GMD is reduced from 1.26d to d, the inductance L decreases and the capacitance C increases.
L=2├Ч10тИТ7ln(GMRGMDтАЛ) тАФ Inductance per unit length
C=ln(rGMDтАЛ)2╧А╧╡тАЛ тАФ Capacitance per unit length
The inductance L of a transmission line is proportional to ln(GMRGMDтАЛ), while the shunt capacitance C is inversely proportional to ln(rGMDтАЛ). By shifting conductors from a horizontal arrangement to an equilateral one, the GMD decreases, which directly reduces the inductance and increases the capacitance due to the logarithmic relationship.
Equilateral spacing results in the smallest GMD for a given inter-conductor distance d.
Horizontal spacing results in unbalanced mutual inductance between phases unless transposed.
Equilateral spacing naturally balances line parameters, reducing the need for complex transposition.
Inductance decreases as GMD decreases; Capacitance increases as GMD decreases.
Balanced line parameters (L and C)
Reduction in voltage unbalance
Structural complexity in tower design
Increased tower height requirements
High Voltage (HV) transmission lines
Long distance power distribution
| Feature | Horizontal GMD | Equilateral GMD |
|---|---|---|
Parameter | 1.26d | d |
GMD is the Geometric Mean Distance, representing the effective distance between conductors.
Option D is the correct choice because reducing the GMD between phases increases the capacitive coupling and decreases the inductive loop area.
D is correct тАФ When conductors are rearranged into an equilateral triangle, the GMD decreases compared to horizontal spacing, causing the inductance to decrease and the capacitance to increase.
Always remember that GMD is the key factor: smaller GMD leads to lower inductance and higher capacitance, which improves surge impedance loading (SIL) characteristics.