Join 60,000+ competitive exam aspirants
A compound pipeline consists of two pieces of identical pipes. The equivalent length of the same diameter and the same friction factor for this compound pipeline is L 1 when the pipes are connected in series and is L 2 when the pipes are connected in parallel. Determine the ratio of equivalent lengths, that is, L 1 to L 2 .
4 : 1
32 : 1
64 : 1
8 : 1
8 : 1
For two pipes of equal length L and diameter D connected in series, the equivalent length L1тАЛ is 2L. For the same two pipes connected in parallel, the equivalent length L2тАЛ is L/4, resulting in a ratio L1тАЛ/L2тАЛ=(2L)/(L/4)=8.
For two pipes of equal length L and diameter D connected in series, the equivalent length L1тАЛ is 2L. For the same two pipes connected in parallel, the equivalent length L2тАЛ is L/4, resulting in a ratio L1тАЛ/L2тАЛ=(2L)/(L/4)=8.
hfтАЛ=2gDfLV2тАЛ тАФ Darcy-Weisbach equation for head loss
L1тАЛ=L+L=2L тАФ Equivalent length in series
L2тАЛ=(L/D5тАЛ1тАЛ+L/D5тАЛ1тАЛ)тИТ2=(L/D5тАЛ2тАЛ)тИТ2=4LтАЛ тАФ Equivalent length in parallel
In series connection, total head loss is the sum of head losses, leading to LeqтАЛ=тИСLiтАЛ. In parallel connection, the equivalent length is derived from the Darcy-Weisbach head loss equation by equating the pressure drop across parallel branches, resulting in LeqтАЛ=(тИСLiтАЛ/Di5тАЛтАЛ1тАЛ)тИТ2.
Series connection increases total resistance (length) while maintaining constant flow rate.
Parallel connection decreases total resistance (equivalent length) while maintaining constant pressure drop.
The equivalent length calculation assumes the diameter and friction factor remain constant across the system.
Simplifies complex pipeline networks into a single imaginary pipe.
Facilitates easier hydraulic gradient line calculation.
Applicable only when friction factors are assumed constant.
Complexity increases significantly for pipes with varying diameters.
Design of water distribution networks.
Hydraulic system analysis in industrial piping.
| Feature | Series Equivalent Length | Parallel Equivalent Length |
|---|---|---|
Connection Type | 2L | L/4 |
The ratio L1тАЛ/L2тАЛ is 2L/(L/4)=8.
Option A (4:1) ignores the squared relationship of the resistance in parallel flow.
D is correct тАФ The ratio of equivalent lengths for two identical pipes in series versus parallel is 8:1.
Remember that in parallel pipes, head loss is identical for both, whereas in series, the discharge is identical; always set up the equality based on what is constant.