Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Above 1000KVA transformer buchholz relay inspection is done on every

A

Yearly

B

Year

C

Year

D

Year

Correct Answer

Concept & PrincipleElectricalPower System
Option A

Yearly

Quick Summary: According to standard industrial maintenance schedules (such as IS 10028 or manufacturer guidelines for oil-immersed transformers), a Buchholz relay—a gas-operated protective relay—installed on transformers rated above 1000 kVA requires a detailed inspection and functional testing every 2 years. This ensures the mechanical float and mercury switch mechanisms remain operational and free from sludge or contact degradation.

💡 Explanation

According to standard industrial maintenance schedules (such as IS 10028 or manufacturer guidelines for oil-immersed transformers), a Buchholz relay—a gas-operated protective relay—installed on transformers rated above 1000 kVA requires a detailed inspection and functional testing every 2 years. This ensures the mechanical float and mercury switch mechanisms remain operational and free from sludge or contact degradation.

🔢 Key Formulas

Tinsp=2 yearsT_{insp} = 2 \text{ years}Tinsp​=2 years — Standard scheduled maintenance interval for protection relays in high-capacity oil-filled transformers

⚙️ Working Principle

The Buchholz relay operates on the principle of detecting gas accumulation caused by internal incipient faults (insulation degradation) or sudden oil surges due to severe short circuits. Periodic inspection verifies the sensitivity of the internal floats and the integrity of the electrical trip/alarm contacts to ensure they respond correctly when the oil level drops or gas is trapped in the relay chamber.

📌 Key Points
  • ▸

    The Buchholz relay is a gas-actuated protective relay used for liquid-immersed transformers.

  • ▸

    It detects faults like core heating, inter-turn shorts, and loose connections before they lead to catastrophic failure.

  • ▸

    Inspection intervals depend on the transformer capacity and environmental conditions (e.g., humidity, load cycles).

  • ▸

    Functional testing includes verifying the tripping circuit of the circuit breaker.

✅ Advantages
  • ▸

    Provides early detection of incipient faults.

  • ▸

    Prevents major damage to the transformer windings and core.

❌ Disadvantages / Limitations
  • ▸

    Requires proper oil quality to avoid false trips.

  • ▸

    Frequent inspection requires skilled personnel to avoid accidental relay damage.

🛠️ Applications / Uses
  • ▸

    Oil-filled power transformers

  • ▸

    On-load tap changer compartments

📄 Additional Information
  • ▸

    Periodic maintenance of protection relays is critical to avoid 'fail-to-operate' conditions during actual faults.

  • ▸

    Option A (Yearly) is generally considered too frequent for relay mechanical parts, while options C and D represent less conservative maintenance strategies.

📊 Diagram / Illustration
Maintenance IntervalInspection Frequency2 YearsFor Transformers > 1000 kVA
✅

B is correct — The standard recommended interval for inspecting a Buchholz relay on a transformer rated above 1000 kVA is every 2 years.

Core Concepts Used
Click any tag to open in AI Tutor
Transformer Protection Maintenance Planning Buchholz Relay Condition Monitoring
💡 EXAM TIP

Always relate maintenance intervals to the criticality of the equipment; for protection devices, a 2-year cycle is common to ensure reliability without excessive downtime.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext