Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Above 1000KVA transformer transformer oil testing is done on every

A

Month

B

Three month

C

Six month

D

Yearly

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option D

Yearly

Quick Summary:

Transformer oil testing is a critical predictive maintenance procedure to assess the dielectric strength and moisture content of the insulating oil. For power transformers rated above 1000 kVA, the Bureau of Indian Standards (BIS) and standard utility practices mandate testing at least once a year to ensure operational reliability.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

Transformer oil testing is a critical predictive maintenance procedure to assess the dielectric strength and moisture content of the insulating oil. For power transformers rated above 1000 kVA, the Bureau of Indian Standards (BIS) and standard utility practices mandate testing at least once a year to ensure operational reliability.

ЁЯФв Key Formulas

BDVminтЙе30kVBDV_{min} \ge 30 kVBDVminтАЛтЙе30kV тАФ Minimum dielectric strength requirement for transformer oil in standard distribution systems.

тЪЩя╕П Working Principle

The testing process involves measuring the Break Down Voltage (BDV) of an oil sample using an oil test set. As the transformer ages, moisture, dissolved gases, and carbon particles accumulate, reducing the dielectric strength. If the BDV falls below the specified threshold (e.g., 30kV for transformers up to 11kV), the oil must be filtered or replaced.

ЁЯУМ Key Points
  • тЦ╕

    Transformer oil performs dual roles as an insulating medium and a heat-transfer coolant.

  • тЦ╕

    BDV test is the primary indicator of the oil's health.

  • тЦ╕

    Moisture and sludge formation are the leading causes of oil degradation.

  • тЦ╕

    Annual testing is the industry standard for large transformers (>1000 kVA) to prevent insulation failure.

тЬЕ Advantages
  • тЦ╕

    Early detection of insulation degradation.

  • тЦ╕

    Prevention of catastrophic transformer failure.

  • тЦ╕

    Extended life of transformer paper insulation.

тЭМ Disadvantages / Limitations
  • тЦ╕

    Requires specialized testing equipment.

  • тЦ╕

    Requires skilled personnel to collect samples without contamination.

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Power Substations

  • тЦ╕

    Large Industrial Transformers

  • тЦ╕

    Grid Connectivity Infrastructure

ЁЯУД Additional Information
  • тЦ╕

    Oil testing frequency is often increased to 6 months or quarterly if the transformer shows signs of overloading or moisture ingression.

  • тЦ╕

    Option A, B, and C are typically reserved for higher-risk transformers, faulty units, or specific environmental conditions.

ЁЯУК Diagram / Illustration
Transformer Oil Maintenance ScheduleRating > 1000 kVATest Frequency: Once per Year
тЬЕ

D is correct тАФ Transformer oil testing for units above 1000 kVA is standardly performed on a yearly basis as part of routine predictive maintenance.

Core Concepts Used
Click any tag to open in AI Tutor
Dielectric Strength Preventive Maintenance Break Down Voltage (BDV)
ЁЯТб EXAM TIP

Always remember that smaller or distribution transformers in harsh environments may require more frequent testing than the 1000 kVA threshold suggests.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext