Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Above 1000KVA transformer On load tap changer inspection is done on every

A

Month

B

Three month

C

Six month

D

Yearly

Correct Answer

Concept & PrincipleElectricalPower System
Option A

Month

Quick Summary: For transformers rated above 1000 kVA, the On-Load Tap Changer (OLTC) contains moving mechanical contacts and insulating oil that degrade due to switching arcs. Therefore, standard industry practice mandates a monthly inspection to monitor contact wear, oil dielectric strength, and the operating mechanism's integrity.

💡 Explanation

For transformers rated above 1000 kVA, the On-Load Tap Changer (OLTC) contains moving mechanical contacts and insulating oil that degrade due to switching arcs. Therefore, standard industry practice mandates a monthly inspection to monitor contact wear, oil dielectric strength, and the operating mechanism's integrity.

🔢 Key Formulas

Vout=Vin×(1±n⋅Δv)V_{out} = V_{in} \times (1 \pm n \cdot \Delta v)Vout​=Vin​×(1±n⋅Δv) — representing voltage regulation via tap position nnn where Δv\Delta vΔv is the percentage change per tap.

⚙️ Working Principle

The OLTC operates by diverting load current through transition resistors while switching between tap positions to maintain voltage stability. Since the switching process involves frequent mechanical stress and localized arcing, the insulating oil becomes contaminated with carbon, necessitating regular inspection to prevent insulation failure or contact welding.

📌 Key Points
  • ▸

    Monthly inspections prevent catastrophic failures of the tap changer mechanism.

  • ▸

    Oil dielectric strength testing is critical because arcing inside the OLTC compartment produces sludge and carbon particles.

  • ▸

    The maintenance cycle depends on the kVA rating and frequency of operation (switching cycles).

  • ▸

    Maintenance typically includes checking the Buchholz relay connected to the OLTC compartment.

✅ Advantages
  • ▸

    Ensures precise voltage regulation under variable load conditions.

  • ▸

    Extends the operational life of transformer winding insulation.

❌ Disadvantages / Limitations
  • ▸

    High maintenance requirement compared to Off-Circuit Tap Changers (OCTC).

  • ▸

    Complexity of mechanical drive systems increases the probability of mechanical failure.

🛠️ Applications / Uses
  • ▸

    Grid distribution substations.

  • ▸

    Industrial transformers with heavy load fluctuations.

  • ▸

    Power transmission transformers requiring autonomous voltage control.

📄 Additional Information
  • ▸

    The 1000 kVA threshold is a standard guideline in the Central Electricity Authority (CEA) guidelines for transformer maintenance in India.

  • ▸

    If the frequency of tap operations is unusually high, the inspection interval may be shortened further based on the manufacturer's operational manual.

  • ▸

    Option D (yearly) is generally considered inadequate for high-capacity transformers due to the rapid accumulation of carbon in the OLTC oil.

📊 Diagram / Illustration
OLTC Maintenance CycleInspection FrequencyEvery 30 Days (1 Month)(For Transformers > 1000 kVA)
✅

A is correct — For transformers rated above 1000 kVA, the OLTC requires a monthly inspection to manage the effects of switching arc-induced oil contamination and mechanical wear.

Core Concepts Used
Click any tag to open in AI Tutor
Tap Changer Maintenance Transformer Oil Dielectric Strength Voltage Regulation
💡 EXAM TIP

Always remember that in power systems, maintenance frequency is directly proportional to the duty cycle of the component; higher kVA ratings almost always demand more frequent routine inspections.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext