Join 60,000+ competitive exam aspirants
Artificial draught is produced by
A forced fan
An induced fan
Induced and forced fan
All of above
All of above
Artificial draught is a mechanical method used in power plants to ensure a consistent flow of air for combustion and the removal of flue gases regardless of atmospheric conditions. It is produced by using mechanical fans, which can be categorized based on their position relative to the boiler furnace.
Artificial draught is a mechanical method used in power plants to ensure a consistent flow of air for combustion and the removal of flue gases regardless of atmospheric conditions. It is produced by using mechanical fans, which can be categorized based on their position relative to the boiler furnace.
PdraughtтАЛ=HgтАЛтЛЕgтЛЕ(╧БairтАЛтИТ╧БgasтАЛ) тАФ represents the theoretical draught pressure head
Q=AтЛЕv тАФ represents the volume flow rate of air/gas through the boiler system
The principle relies on generating a pressure difference across the furnace using fans. In forced draught, a fan forces air into the furnace, maintaining a positive pressure. In induced draught, a fan located at the chimney base draws flue gases out, creating a negative pressure. Balanced draught combines both, using a forced fan to provide combustion air and an induced fan to extract exhaust gases, maintaining near-atmospheric pressure within the furnace.
Artificial draught is independent of ambient temperature and chimney height.
It allows for the use of economizers and air preheaters which increase flue gas resistance.
Balanced draught is the most common system in large-scale modern power plants.
The power required for a fan is proportional to the cube of the speed: PтИЭN3.
Better control over combustion rates
Independent of atmospheric fluctuations
Allows for taller, more efficient boilers
High initial and maintenance costs
Requires external electrical power supply
Complexity of system operation
Thermal Power Plants
Industrial Steam Generators
Incineration Plants
| Feature | Forced Draught | Induced Draught |
|---|---|---|
Pressure Profile | Positive Pressure | Negative Pressure |
Natural draught relies solely on chimney height and buoyancy, which is insufficient for modern high-capacity boilers.
In balanced draught, the forced draught fan supplies air at pressure, and the induced draught fan maintains the draft at the outlet, preventing smoke leakage into the boiler room.
D is correct тАФ Artificial draught is achieved through mechanical means using forced, induced, or combined fan systems to regulate boiler combustion.
Always remember that in a Balanced Draught system, the forced fan is placed before the furnace and the induced fan is placed after the economizer/air preheater.