At what pressure is the SF6 gas filled in the whole installation of GIS substations?
kg / cm2
kg / cm2
kg / m2
kg / m2
kg / cm2
Sulfur Hexafluoride (SF6тАЛ) gas is used in Gas Insulated Substations (GIS) as an insulating and arc-quenching medium. The pressure in GIS is typically maintained in the range of 3 to 5 kg/cm2 (or approximately 0.3 to 0.5 MPa) at standard temperature to ensure high dielectric strength.
Sulfur Hexafluoride (SF6тАЛ) gas is used in Gas Insulated Substations (GIS) as an insulating and arc-quenching medium. The pressure in GIS is typically maintained in the range of 3 to 5 kg/cm2 (or approximately 0.3 to 0.5 MPa) at standard temperature to ensure high dielectric strength.
VbdтАЛ=ln(AтЛЕPтЛЕd/ln(1+1/╬│))BтЛЕPтЛЕdтАЛ тАФ Paschen's Law for breakdown voltage
PтЙИ3тИТ5kg/cm2 тАФ Typical GIS operational pressure range
The SF6тАЛ molecule is highly electronegative, meaning it readily captures free electrons to form heavy, low-mobility negative ions. This property effectively halts the ionization process (electron avalanche) required for an electrical discharge. By maintaining the gas at an elevated pressure of several kg/cm2, the particle density increases, which significantly raises the breakdown voltage (VbтАЛ) according to Paschen's Law.
SF6тАЛ is chemically inert, non-toxic, and non-flammable under normal conditions.
Higher pressure allows for compact GIS design by reducing the clearance required between live parts and the grounded enclosure.
The pressure must be monitored constantly as gas density directly correlates with dielectric performance.
Pressure is often expressed in bar or kg/cm2 (where 1barтЙИ1.02kg/cm2).
Excellent arc quenching capability
High dielectric strength reducing substation footprint
Completely sealed environment protected from pollution
High global warming potential of SF6тАЛ gas
Requires strict leak detection and monitoring systems
High-voltage circuit breakers
Gas-insulated switchgear (GIS)
Gas-insulated transmission lines (GIL)
In practice, the actual filling pressure is carefully selected based on the voltage class of the GIS (e.g., 145kV, 420kV).
Options C and D are incorrect because kg/m2 is not a standard engineering unit for gas pressure in electrical switchgear.
A is correct тАФ The pressure of SF6тАЛ gas in GIS is measured in kg/cm2 to ensure optimal dielectric strength.
Always remember that SF6тАЛ is a dense gas; its insulating capability is directly proportional to its pressure and density, making precise pressure management vital for preventing internal flashovers.