Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Buchholz relay is used for transformer rating above

A

100┬аKVA100\text{ KVA}100┬аKVA

B

200┬аKVA200\text{ KVA}200┬аKVA

C

400┬аKVA400\text{ KVA}400┬аKVA

D

500┬аKVA500\text{ KVA}500┬аKVA

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option D

500┬аKVA500\text{ KVA}500┬аKVA

Quick Summary:

The Buchholz relay is a gas-actuated protective device installed in oil-immersed transformers to detect incipient faults. According to IS 3639, it is mandatory for oil-immersed transformers with ratings of 500 KVA and above to ensure reliable protection against internal electrical faults.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

The Buchholz relay is a gas-actuated protective device installed in oil-immersed transformers to detect incipient faults. According to IS 3639, it is mandatory for oil-immersed transformers with ratings of 500 KVA and above to ensure reliable protection against internal electrical faults.

ЁЯФв Key Formulas

PfaultтИЭd╬жdtP_{fault} \propto \frac{d\Phi}{dt}PfaultтАЛтИЭdtd╬жтАЛ тАФ representation of fault gas generation due to arcing

тЪЩя╕П Working Principle

The relay is placed in the connecting pipe between the transformer tank and the conservator. When a minor fault occurs, insulating oil decomposes to produce gases that collect in the relay, causing the upper float to tilt and close the alarm circuit. For severe faults, a sudden pressure wave or high oil flow activates the lower float, which trips the circuit breaker to isolate the transformer.

ЁЯУМ Key Points
  • тЦ╕

    Used for oil-immersed power transformers only.

  • тЦ╕

    Categorized as a mechanical protection device.

  • тЦ╕

    Capable of detecting internal faults like insulation failure, core heating, and winding short circuits.

  • тЦ╕

    Not suitable for external faults or tank leakages.

тЬЕ Advantages
  • тЦ╕

    Detects incipient faults before they become severe.

  • тЦ╕

    Simple construction and maintenance.

тЭМ Disadvantages / Limitations
  • тЦ╕

    Applicable only for oil-filled transformers.

  • тЦ╕

    Requires minimum oil level to function.

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Oil-immersed power transformers.

  • тЦ╕

    Large distribution transformers (тЙе 500 KVA).

ЁЯУД Additional Information
  • тЦ╕

    The Buchholz relay is named after Max Buchholz, who invented the device in 1921.

  • тЦ╕

    Ratings below 500 KVA generally rely on simpler protection methods like fuses or secondary circuit breakers because the cost-to-risk ratio does not justify the installation of a Buchholz relay.

ЁЯУК Diagram / Illustration
Buchholz Relay LocationTransformerConservatorBuchholz Relay (500+ KVA)
тЬЕ

D is correct тАФ The Buchholz relay is standard protection for oil-immersed transformers rated 500 KVA and above.

Core Concepts Used
Click any tag to open in AI Tutor
Transformer Protection Gas-actuated relays Incipient fault detection
ЁЯТб EXAM TIP

Always remember that Buchholz relays cannot function on dry-type transformers as they rely on the generation of gases from the breakdown of insulating transformer oil.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext