Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Which of the protection is provided by buchholz relay?

A

Short circuit in winding

B

Earth fault in winding

C

Local over heating

D

All of above

Correct Answer

Concept & PrincipleElectricalPower System
Option D

All of above

Quick Summary: The Buchholz relay is a gas-actuated protective device installed in oil-immersed transformers to provide comprehensive protection against various internal incipient faults. It detects the accumulation of gas or sudden surges in oil pressure, triggered by arcs, short circuits, or insulation degradation.

💡 Explanation

The Buchholz relay is a gas-actuated protective device installed in oil-immersed transformers to provide comprehensive protection against various internal incipient faults. It detects the accumulation of gas or sudden surges in oil pressure, triggered by arcs, short circuits, or insulation degradation.

🔢 Key Formulas

Pfault∝Ifault2P_{fault} \propto I^2_{fault}Pfault​∝Ifault2​ — Relation between internal fault intensity and gas production rate

⚙️ Working Principle

During an internal fault, the arc decomposes transformer oil into gases like hydrogen, methane, and carbon monoxide. These gases collect in the relay chamber, displacing oil and tilting the float switch to initiate an alarm. If a severe fault causes a rapid pressure wave, the lower float trips the main circuit breaker to isolate the transformer.

📌 Key Points
  • ▸

    Buchholz relay is used exclusively for oil-immersed transformers (rated above 500 kVA).

  • ▸

    It cannot detect external faults or faults in the secondary circuit wiring.

  • ▸

    The relay operates on the principle of gas accumulation or sudden oil flow velocity.

  • ▸

    It provides both alarm (for minor faults) and trip (for major faults) signals.

✅ Advantages
  • ▸

    Detects incipient faults at a very early stage before they become severe.

  • ▸

    Simple and reliable mechanical construction.

❌ Disadvantages / Limitations
  • ▸

    Applicable only to oil-immersed transformers equipped with a conservator tank.

  • ▸

    Cannot detect faults occurring outside the transformer tank (e.g., in bushings or cables).

🛠️ Applications / Uses
  • ▸

    Oil-immersed power and distribution transformers.

  • ▸

    Tap-changing equipment compartments.

📄 Additional Information
  • ▸

    Minor faults include local overheating, core insulation failure, and loose electrical connections.

  • ▸

    Major faults include phase-to-phase short circuits and earth faults causing sudden pressure surges.

📊 Diagram / Illustration
Buchholz Relay MechanismFault Heat/ArcGas GenerationTrip / Alarm
✅

D is correct — The Buchholz relay is designed to detect all internal faults, including short circuits, earth faults, and local overheating, by monitoring gas generation and oil surge within the transformer tank.

Core Concepts Used
Click any tag to open in AI Tutor
Gas-actuated protection Internal incipient faults Transformer oil decomposition
💡 EXAM TIP

Remember that Buchholz relay is a 'slow' protection device; it is not instantaneous and is meant for internal faults, unlike Differential protection which is fast but covers only the transformer zone.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext