Join 60,000+ competitive exam aspirants
Capacity factor will be very low when the power plant
Is operated as base load plant
Is operated for supplying base loads as well as peak loads
Is operated in emergency only
Is under maintenance
Is operated in emergency only
The Capacity Factor is the ratio of the actual energy generated by a power plant over a period to the maximum possible energy it could have produced if operated at full rated capacity for the entire period. When a plant is operated only for emergencies, its actual energy output is extremely low relative to its capacity, resulting in a very low capacity factor.
The Capacity Factor is the ratio of the actual energy generated by a power plant over a period to the maximum possible energy it could have produced if operated at full rated capacity for the entire period. When a plant is operated only for emergencies, its actual energy output is extremely low relative to its capacity, resulting in a very low capacity factor.
CF=Rated┬аCapacity├ЧTime┬аPeriodActual┬аEnergy┬аGeneratedтАЛ
Capacity┬аFactor=Plant┬аCapacityAverage┬аLoadтАЛ
The factor is defined as Max┬аPossible┬аEnergyActual┬аEnergy┬аProducedтАЛ. If a plant (like a peaking plant or standby reserve) runs for only a few hours per year during emergency conditions, the numerator remains very small while the denominator (Rating ├Ч Time) stays fixed based on the total period, forcing the ratio toward zero.
Capacity factor is a measure of the utilization of a power plant.
Base load plants typically have high capacity factors (often 70-90%).
Peaking plants or emergency backup plants have low capacity factors (often 5-15%).
It is always less than or equal to the load factor.
Provides a clear indicator of plant economic viability.
Helps in estimating fuel requirements and maintenance scheduling.
Does not account for the efficiency of the power generation process.
A low capacity factor might indicate an over-invested capital asset if not intended for peaking.
Grid stability planning.
Evaluating the necessity of plant capacity additions.
Economic dispatch calculation.
Base load plants (like Nuclear or Coal) run continuously and thus achieve high capacity factors.
Option A is incorrect because base load plants require high utilization for economic operation.
Option D describes an 'Outage' period, but 'Emergency operation' is the standard operational definition for extremely low utility.
C is correct тАФ A power plant operated only in emergencies has a very low actual energy output over a year, leading to a negligible capacity factor.
In exams, always distinguish between Capacity Factor (Plant capability) and Load Factor (Consumer behavior); remember that Capacity Factor тЙд Load Factor.