Join 60,000+ competitive exam aspirants
Consider the following statements: In the case of suspension type insulators, the string efficiency can be improved by
Using a longer cross arm
Using a guard ring
Grading the insulator discs
Reducing the cross arm length
1 and 3 are correct
1, 2 and 3 are correct
2, 3 and 4 are correct
2 and 4 are correct
1, 2 and 3 are correct
String efficiency in suspension insulators is the ratio of flashover voltage of the whole string to the product of the number of discs and the flashover voltage of the individual disc. Increasing this efficiency is achieved by equalizing the voltage distribution across all discs in the string.
String efficiency in suspension insulators is the ratio of flashover voltage of the whole string to the product of the number of discs and the flashover voltage of the individual disc. Increasing this efficiency is achieved by equalizing the voltage distribution across all discs in the string.
╬╖=n├ЧVdiscтАЛVstringтАЛтАЛ тАФ Definition of string efficiency
CshuntтАЛтИЭd1тАЛ тАФ Relationship where increasing cross-arm length d decreases shunt capacitance
In a string of insulators, the capacitance between each disc and the tower (shunt capacitance) causes uneven voltage distribution, resulting in higher stress on the disc nearest to the conductor. Using a longer cross arm reduces shunt capacitance, a guard ring equalizes potential distribution by creating a compensating current, and grading the discs (using discs of different capacitances) ensures the capacitive reactance matches the required potential drops.
String efficiency is 100% only if the voltage across each disc is identical.
The guard ring effectively reduces the shunt capacitance current by providing a path for charging current to the string.
Grading involves increasing the capacitance of the lower discs relative to the upper ones.
Reduces the risk of insulator flashover
Improves reliability of high voltage transmission lines
Guard rings increase the overall weight and cost of the assembly
Graded discs require specialized inventory and inventory management
High Voltage overhead power transmission lines
Extra High Voltage (EHV) substations
Reducing the cross-arm length (Option 4) would actually increase shunt capacitance, making voltage distribution worse and lowering string efficiency.
Statement 1, 2, and 3 are standard engineering practices to optimize potential distribution.
B is correct тАФ Using a longer cross-arm, installing a guard ring, and grading discs are all established techniques to minimize voltage inequality across suspension insulator strings.
Always remember that the disc closest to the conductor experiences the highest potential; therefore, all correction methods aim to relieve the stress on this specific disc.